Right pulmonary to left pulmonary perfusion ratio after percutaneous pulmonary valve implantation
نویسندگان
چکیده
Background Percutaneous pulmonary valve implantation (PPVI) requires the positioning of a stiff guidewire into one of the pulmonary branch arteries. An infrequent but commonly known complication is the “jailing” of one of the pulmonary branch arteries. However, even without apparent “jailing” of one of the pulmonary branch arteries, we suspect that the technique of stent placements often has an effect on the pulmonary perfusion ratio. The aim of this study was to assess the changes of the pulmonary perfusion ratio and their predictors after PPVI.
منابع مشابه
Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease
Introduction: In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...
متن کاملIntegrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty
Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...
متن کاملTransient complete atrioventricular block after percutaneous pulmonary valve implantation.
Percutaneous pulmonary valve implantation for conduit dysfunction in the right ventricular outflow tract is a safe and efficient treatment in selected patients. We report on a patient with stenosis and regurgitation of a homograft in the right ventricular outflow tract who developed complete atrioventricular block during percutaneous implantation of a Melody™ valve. This complete atrioventricul...
متن کاملOutcomes of Pulmonary Valve Replacement for Correction Pulmonary Insufficiency after Primary Repair of Tetralogy of Fallot (TOF)
Background Total correction of Tetralogy of Fallot (TOF) anomaly in early childhood has been practiced in many centers with good results, but in some of patients after few years sever Pulmonary valve insufficiency occurred. Materials and Methods At a cross- sectional study from January 2015 to January 2016, 10 patients who had history of primary repair of TOF with free pulmonary insufficiency (...
متن کاملImplantation of the Medtronic Harmony Transcatheter Pulmonary Valve Improves Right Ventricular Size and Function in an Ovine Model of Postoperative Chronic Pulmonary Insufficiency.
BACKGROUND Pulmonary insufficiency is the nexus of late morbidity and mortality after transannular patch repair of tetralogy of Fallot. This study aimed to establish the feasibility of implantation of the novel Medtronic Harmony transcatheter pulmonary valve (hTPV) and to assess its effect on pulmonary insufficiency and ventricular function in an ovine model of chronic postoperative pulmonary i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -