Free-depths reconstruction with synthetic impulse response in integral imaging.
نویسندگان
چکیده
Integral Imaging provides spatial and angular information of three-dimensional (3D) objects, which can be used both for 3D display and for computational post-processing purposes. In order to recover the depth information from an integral image, several algorithms have been developed. In this paper, we propose a new free depth synthesis and reconstruction method based on the two-dimensional (2D) deconvolution between the integral image and a simplified version of the periodic impulse response function (IRF) of the system. The period of the IRF depends directly on the axial position within the object space. Then, we can retrieve the depth information by performing the deconvolution with computed impulse responses with different periods. In addition, alternative reconstructions can be obtained by deconvolving with non-conventional synthetic impulse responses. Our experiments show the feasibility of the proposed method as well as its potential applications.
منابع مشابه
Fast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کامل2D DC resistivity forward modeling based on the integral equation method and a comparison with the RES2DMOD results
A 2D forward modeling code for DC resistivity is developed based on the integral equation (IE) method. Here, a linear relation between model parameters and apparent resistivity values is proposed, although the resistivity modeling is generally a nonlinear problem. Two synthetic cases are considered for the numerical calculations and the results derived from IE code are compared with the RES2DMO...
متن کاملImproving the quality of ultrasound images using Bayesian estimators
Medical ultrasound imaging due to close behavior of cancer tumors to body tissues has a low contrast. This problem with synthetic aperture imaging method has been addressed. Although the synthetic aperture imaging technique solved the low-contrast problem of ultrasound images, to an acceptable limit, but the performance of these methods is not even acceptable when the signal to noise ratio (SNR...
متن کاملConventional Voxel in Tomographic Reconstruction Based upon Plane-Integral Projections – Use It or Lose It?
Introduction: While the necessity of replacing voxels with blobs in conventional tomographic reconstruction based upon line-integrals is clear, it is not however well-investigated in plane- integral-based reconstruction. The problem is more challenging in convergent-plane projection reconstruction. In this work, we are aiming at utilizing blobs as alternative to voxels. <stron...
متن کاملMagnetic Resonance in Medicine 63:502–509 (2010) IIR GRAPPA for Parallel MR Image Reconstruction
Accelerated parallel MRI has advantage in imaging speed, and its image quality has been improved continuously in recent years. This paper introduces a two-dimensional infinite impulse response model of inverse filter to replace the finite impulse response model currently used in generalized autocalibrating partially parallel acquisitions class image reconstruction methods. The infinite impulse ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 23 23 شماره
صفحات -
تاریخ انتشار 2015