Clinical properties of a novel, glistening-free, single-piece, hydrophobic acrylic IOL
نویسندگان
چکیده
A new, single-piece, hydrophobic acrylic lens - the first constructed with a lens optic and haptics comprised of a hydroxyethyl methacrylate-polyethylene glycol phenyl ether acrylate-styrene copolymer, cross-linked with ethylene glycol dimethacrylate, and labeled as "glistening-free" - was recently introduced globally. Glistenings have been a significant source of clinical concern with previous hydrophobic lens designs. This new monofocal lens provides enhanced, clear optics for lens-based surgery. The superior optical clarity of this lens is achieved through the elimination of glistenings, enhanced surface durability, high refractive index, a high Abbe number, and an aspheric design. Additionally, the lens design reduces the risk of developing posterior capsule opacification.
منابع مشابه
Assessment of new-generation glistening-free hydrophobic acrylic intraocular lens material.
PURPOSE To determine the hydrophobic, antiglistening, and bioadhesiveness properties of a new polymer, GF raw material, and to determine the suitability of this material for use in intraocular lenses (IOLs). SETTING University of Liege, Liege, Belgium. DESIGN Experimental study. METHODS Intraocular lenses made of the new hydrophobic acrylic material were tested and compared with reference...
متن کاملSingle versus three piece acrylic IOLs.
S ince their clinical introduction 10 years ago, hydrophobic acrylic IOLs have gone on to become the most popular foldable IOL category worldwide. According to the annual Leaming surveys of the American Society of Cataract and Refractive Surgery membership, hydrophobic acrylic has been the most preferred IOL material since 1998, and was favoured by 63% of respondents in the 2002 poll. This sust...
متن کاملSafety and effectiveness of a glistening-free single-piece hydrophobic acrylic intraocular lens (enVista)
PURPOSE To evaluate the safety and effectiveness of a single-piece hydrophobic acrylic intraocular lens (IOL; enVista model MX60; Bausch & Lomb, Rochester, NY, USA) when used to correct aphakia following cataract extraction in adults. METHODS This was a prospective case series (NCT01230060) conducted in private practices in the US. Eligible subjects were adult patients with age-related catara...
متن کاملAnalysis of glistenings in hydrophobic acrylic intraocular lenses on visual performance.
AIM To assess patients' visual performance with glistenings in one piece soft hydrophobic acrylic intraocular lenses (IOLs) (Alcon) 2 years postoperatively. METHODS This cross section trial included 120 eyes with one piece IOL at 2 years postoperatively. Glistening was classified in 4 groups, ranging from 0 (none) to 3 (most evident) according to their severity in IOLs optics observed under a...
متن کاملEffect of heparin surface modification in reducing silicone oil adherence to various intraocular lenses.
PURPOSE To evaluate surface properties of various intraocular lenses (IOLs), including a newly fabricated heparin-surface-modified (HSM) silicone IOL, with special reference to their efficiency in reducing potential silicone oil adherence to the IOL optics. SETTING Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University o...