Oculomotor tracking strategy in normal subjects with and without simulated scotoma.
نویسندگان
چکیده
PURPOSE Experiments were conducted on five subjects with no visual impairment to assess tracking strategy differences in subjects with and without a simulated central scotoma. METHODS Subjects were asked to visually track horizontally moving periodic and nonperiodic sinusoidal stimuli through a +/-5 degrees range. Scotoma simulation was achieved electronically with a closed-loop feedback system using horizontal eye movement measurements from a monocular limbus eye tracker updated at a rate of 500 Hz. The scotoma was centrally located and had defined horizontal half widths of 1, 2, and 3 degrees . Vertical eye position measurements from a video-based dark-pupil tracker were used to identify and remove trials in which extreme vertical eye position deviations reduced the effectiveness of the simulation. RESULTS All subjects developed a preferred retinal locus (PRL) in the left visual field and demonstrated a tendency for saccadic redirection to this area. Saccadic endpoints into the PRL outnumbered foveally directed saccades by a factor of 2:1. The PRL was located outside the compromised central vision region, typically near the edge of the scotoma boundary, for all subjects except one. This subject had a PRL within the simulated scotoma under two conditions, but the percentage of total time spent at the "compromised" PRL was less than for other subjects. CONCLUSIONS Subjects with no visual impairment confronted with a central scotoma develop a preferred retinal locus to replace the nonfunctional fovea and appear to suppress normal refoveating saccadic behavior in favor of this location.
منابع مشابه
Assessment of reading behavior with an infrared eye tracker after 360° macular translocation for age-related macular degeneration.
PURPOSE. Macular translocation (MT360) is complex surgery used to restore reading in exudative age-related macular degeneration (AMD). MT360 involves retinal rotation and subsequent oculomotor globe counterrotation and is not without significant surgical risk. This study attempts to gauge the optimal potential of MT360 in restoring reading ability and describe the quality and extent of recovery...
متن کاملIntegrating oculomotor and perceptual training to induce a pseudofovea: A model system for studying central vision loss
People with a central scotoma often adopt an eccentric retinal location (Preferred Retinal Locus, PRL) for fixation. Here, we proposed a novel training paradigm as a model system to study the nature of the PRL formation and its impacts on visual function. The training paradigm was designed to effectively induce a PRL at any intended retinal location by integrating oculomotor control and pattern...
متن کاملRapid and Persistent Adaptability of Human Oculomotor Control in Response to Simulated Central Vision Loss
The central region of the human retina, the fovea, provides high-acuity vision. The oculomotor system continually brings targets of interest into the fovea via ballistic eye movements (saccades). Thus, the fovea serves both as the locus for fixations and as the oculomotor reference for saccades. This highly automated process of foveation is functionally critical to vision and is observed from i...
متن کاملThe effects of simulated cataract on reading with normal vision and simulated central scotoma
Reading rates are slower for persons with low vision than for normally-sighted persons. This study investigated the change in reading performance and reading eye movements when we simulated the two most common causes of low vision--central field loss and cataract--and their combination (scotoma + cataract). Three subjects read sentences with each of these simulated impairments at five different...
متن کاملThe effect of simulated scotomas on visual search in normal subjects.
A simulated scotoma was stabilized on the fovea of 23 normal human subjects while they searched for acuity targets in arrays of non-targets. Search time doubled with a 20 min arc scotoma, and eye fixation duration increased by about 15% when compared to no-scotoma control conditions. Search difficulty was graded by adjusting acuity target size, search element density and contrast. Search time a...