[Protein micro-crystallography with a new micro-beam beamline].

نویسندگان

  • Masaki Yamamoto
  • Kunio Hirata
  • Takaaki Hikima
  • Yoshiaki Kawano
  • Go Ueno
چکیده

Recently, researchers' demands for high-quality data collection from protein micro-crystals, which would usually result from crystallization difficulty, have been remarkably growing. In order to collect efficient diffraction data for structure determination from micro-crystals, an expert data collection system providing high signal-to-noise ratio should be essential. A small sized and highly brilliant X-ray beam with size of a few micrometers has been proved to achieve protein micro-crystallography by both increasing reflection intensities and reducing background scattering from sample environments. Two micro-beam beamlines at SPring-8 and KEK-PF are currently under construction for Targeted Proteins Research Program by MEXT of Japan. At SPring-8, a new undulator beamline for protein micro-crystallography, named RIKEN Targeted Proteins Beamline (BL32XU), will start operation in May, 2010. The beam size at sample position of BL32XU will correspond to 1 x 1 microm(2) with the photon flux density over 6 x 10(10) photons/s/microm(2). Furthermore, research and developments of indispensable components to achieve protein micro-crystallography with micro-beam, such as high-precision diffractometer, automated micro-crystal handling, advanced data collection system to suppress radiation damage and so on, are progressing. The present status of the research and development for protein micro-crystallography will be presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline BL-17A

BL-17A is a macromolecular crystallography beamline dedicated to diffraction experiments conducted using micro-crystals and structure determination studies using a lower energy X-ray beam. In these experiments, highly accurate diffraction intensity measurements are definitively important. Since this beamline was constructed, the beamline apparatus has been improved in several ways to enable the...

متن کامل

[Advancement of synchrotron radiation protein crystallography in the targeted protein research program: beamline developments at the photon factory].

The Targeted Protein Research Program (TPRP) started in 2007 as a sequel of the Protein 3000 Project which lasted from 2002 to 2007. In the new project, four cores, Protein Production, Structure Analysis, Control of Protein Functions with Compounds, and Informatics, have been established as focus of methodology developments critical for functional and structural studies by the target protein re...

متن کامل

SPring-8 BL41XU, a high-flux macromolecular crystallography beamline

SPring-8 BL41XU is a high-flux macromolecular crystallography beamline using an in-vacuum undulator as a light source. The X-rays are monochromated by a liquid-nitrogen-cooling Si double-crystal monochromator, and focused by Kirkpatrick-Baez mirror optics. The focused beam size at the sample is 80 µm (H) × 22 µm (V) with a photon flux of 1.1 × 10(13) photons s(-1). A pinhole aperture is used to...

متن کامل

Optimization of Beamline BL41XU for Measurement of Micro-Protein Crystal

A number of protein crystallography techniques have been improved in recent years. With this advancement, many kinds of not only soluble protein but also biological important molecule such as protein complexes and membrane proteins have been analyzed. When such proteins are crystallized, it is difficult to obtain a crystal with a suitable size for the diffraction experiment (~ 100 μm) though we...

متن کامل

How the ESRF helps industry and how they help the ESRF

The ESRF has worked with, and provided services for, the pharmaceutical industry since the construction of its first protein crystallography beamline in the mid-1990s. In more recent times, industrial clients have benefited from a portfolio of beamlines which offer a wide range of functionality and beam characteristics, including tunability, microfocus and micro-aperture. Included in this portf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan

دوره 130 5  شماره 

صفحات  -

تاریخ انتشار 2010