The determination of INR in stored whole blood.

نویسندگان

  • D R Leeming
  • S Craig
  • K J Stevenson
  • D A Taberner
چکیده

AIMS To examine the reliability of international normalised ratio (INR) determination on samples stored as whole blood for up to two days at room temperature. METHODS The INR of 40 patients receiving oral anticoagulants was determined on fresh blood and on samples stored for 24 and 48 hours, using five locally calibrated prothrombin time systems. These incorporated Manchester reagent, Recombiplastin, IL PT Fibrinogen HS Plus, Manchester combined capillary prothrombin time reagent, and a freeze dried in-house reference rabbit brain thromboplastin, RBT 1010. In addition, factors II, V, VII, and X were determined on samples obtained from 18 of these patients before and after incubation at room temperature. RESULTS The INR of the samples changed by differing amounts during storage, depending on which system was employed. Although the mean change after 24 hours storage was relatively small, there were individual samples that changed by > 0.5 INR with all systems. These changes would lead to adjustment in dosage of certain patients. After 48 hours these effects were greater with all systems except that employing Recombiplastin. There were only small reduction in the measured factors by 48 hours. CONCLUSIONS After storage of samples for only 24 hours, some patients' INR changed sufficiently to affect dosage. In view of these observations, the practice of storing whole blood samples for INR determination cannot be recommended.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Alterations of Plasma Iipid Peroxidation and erythrocyte Superoxide Dismutase and Glutathione Peroxidase Enzyme Activities During Storage of Blood

Abstract Background and objective: Exposure of red blood cells to oxygen radicals can induce Lipid proxidation, hemoglobin damage and hemolysis of erythrocyte .The present study was designed to determine the alteration of plasma lipid peroxidation and erythrocyte Superoxide Dismutase and Glutathione Peroxidase enzyme activities in stored blood and to find out the quantitative alterations and th...

متن کامل

Stereospecific Determination of Mefloquine in Whole Blood by HPLC

Mefloquine, as a racemic mixture, is used for the treatment and prophylaxis of malaria. Stereoselective pharmacodynamic and pharmacokinetic differences has been observed for mefloquine. In this study a modified stereoselective HPLC method is presented for determination of mefloquine (MFQ) enantiomers in whole blood. The assay involved liquid-liquid extraction of MFQ from biological fluids with ...

متن کامل

Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/international normalized ratio test and implications for monitoring of oral anticoagulant therapy.

BACKGROUND The quality of oral anticoagulant therapy management with coumarin derivatives requires reliable results for the prothrombin time/International Normalized Ratio (PT/INR). We assessed the effect on PT/INR of preanalytical variables, including ones related to off-site blood collection and transportation to a laboratory. METHODS Four laboratories with different combinations of blood c...

متن کامل

Coexistence of anticoagulant and anti-vascular calcification activities in Kribbella sp. UTMC 267 metabolites

Thrombotic disorders increase the risk of cardiovascular/cerebrovascular complications and represent a major health problem worldwide. Anticoagulants are extensively used in treatment of these disorders. Vitamin K antagonists, like Warfarin, are frequently used in medication. Vascular calcification (VC) is a significant side-effect of vitamin K antagonists especially Warfarin. There is an urgen...

متن کامل

Performance of point-of-care international normalized ratio measurement to diagnose trauma-induced coagulopathy

BACKGROUND Trauma-induced coagulopathy (TIC) is a common feature after severe trauma. Detection of TIC is based upon classic coagulation tests including international normalized ratio (INR) value. Point-of-care (POC) devices have been developed to rapidly measure INR at the bedside on whole blood. The aim of the study was to test the precision of the Coagucheck® XS Pro device for INR measuremen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 51 5  شماره 

صفحات  -

تاریخ انتشار 1998