Passive leg raising can predict fluid responsiveness in patients placed on venovenous extracorporeal membrane oxygenation

نویسندگان

  • Pierre-Grégoire Guinot
  • Elie Zogheib
  • Mathieu Detave
  • Mona Moubarak
  • Vincent Hubert
  • Louise Badoux
  • Eugénie Bernard
  • Patricia Besserve
  • Thierry Caus
  • Hervé Dupont
چکیده

INTRODUCTION In ICUs, fluid administration is frequently used to treat hypovolaemia. Because volume expansion (VE) can worsen acute respiratory distress syndrome (ARDS) and volume overload must be avoided, predictive indicators of fluid responsiveness are needed. The purpose of this study was to determine whether passive leg raising (PLR) can be used to predict fluid responsiveness in patients with ARDS treated with venovenous extracorporeal membrane oxygenation (ECMO). METHODS We carried out a prospective study in a university hospital surgical ICU. All patients with ARDS treated with venovenous ECMO and exhibiting clinical and laboratory signs of hypovolaemia were enrolled. We measured PLR-induced changes in stroke volume (ΔPLRSV) and cardiac output (ΔPLRCO) using transthoracic echocardiography. We also assessed PLR-induced changes in ECMO pump flow (ΔPLRPO) and PLR-induced changes in ECMO pulse pressure (ΔPLRPP) as predictors of fluid responsiveness. Responders were defined by an increase in stroke volume (SV) > 15% after VE. RESULTS Twenty-five measurements were obtained from seventeen patients. In 52% of the measurements (n = 13), SV increased by > 15% after VE (responders). The patients' clinical characteristics appeared to be similar between responders and nonresponders. In the responder group, PLR significantly increased SV, cardiac output and pump flow (P < 0.001). ΔPLRSV values were correlated with VE-induced SV variations (r² = 0.72, P = 0.0001). A 10% increased ΔPLRSV predicted fluid responsiveness with an area under the receiver operating characteristic curve (AUC) of 0.88 ± 0.07 (95% confidence interval (CI95): 0.69 to 0.97; P < 0.0001), 62% sensitivity and 92% specificity. On the basis of AUCs of 0.62 ± 0.11 (CI₉₅: 0.4 to 0.8; P = 0.31) and 0.53 ± 0.12 (CI₉₅: 0.32 to 0.73, P = 0.79), respectively, ΔPLRPP and ΔPLRPO did not predict fluid responsiveness. CONCLUSIONS In patients treated with venovenous ECMO, a > 10% ΔPLRSV may predict fluid responsiveness. ΔPLRPP and ΔPLRPO cannot predict fluid responsiveness.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive Leg-Raising and Prediction of Fluid Responsiveness: Systematic Review.

Fluid boluses are often administered with the aim of improving tissue hypoperfusion in shock. However, only approximately 50% of patients respond to fluid administration with a clinically significant increase in stroke volume. Fluid overload can exacerbate pulmonary edema, precipitate respiratory failure, and prolong mechanical ventilation. Therefore, it is important to predict which hemodynami...

متن کامل

Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transoesophageal echocardiographic automated border detection in mechanically ventilated patients

BACKGROUND Left ventricular stroke area by transoesophageal echocardiographic automated border detection has been shown to be strongly correlated to left ventricular stroke volume. Respiratory variations in left ventricular stroke volume or its surrogates are good predictors of fluid responsiveness in mechanically ventilated patients. We hypothesised that respiratory variations in left ventricu...

متن کامل

Clinical use of venovenous extracorporeal membrane oxygenation.

Extracorporeal membrane oxygenation has been used clinically for more than 40 years. The technique provides respiratory and/or circulatory support via venovenous and veno-arterial configurations, respectively. We review the basic physiological principles of extracorporeal membrane oxygenation systems in venovenous extracorporeal membrane oxygenation. Clinical aspects including patient selection...

متن کامل

Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study

INTRODUCTION The assessment of volume responsiveness and the decision to administer a fluid bolus is a common dilemma facing physicians caring for critically ill patients. Static markers of cardiac preload are poor predictors of volume responsiveness, and dynamic markers are often limited by the presence of spontaneous respirations or cardiac arrhythmias. Passive leg raising (PLR) represents an...

متن کامل

Can endotracheal bioimpedance cardiography assess hemodynamic response to passive leg raising following cardiac surgery?

BACKGROUND The utility of endotracheal bioimpedance cardiography (ECOM) has been scarcely reported. We tested the hypothesis that it could be an alternative to pulse contour analysis for cardiac index measurement and prediction in fluid responsiveness. METHODS Twenty-five consecutive adult patients admitted to the intensive care unit following conventional cardiac surgery were prospectively i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -