Improving Intensity-Based Lung CT Registration Accuracy Utilizing Vascular Information
نویسندگان
چکیده
Accurate pulmonary image registration is a challenging problem when the lungs have a deformation with large distance. In this work, we present a nonrigid volumetric registration algorithm to track lung motion between a pair of intrasubject CT images acquired at different inflation levels and introduce a new vesselness similarity cost that improves intensity-only registration. Volumetric CT datasets from six human subjects were used in this study. The performance of four intensity-only registration algorithms was compared with and without adding the vesselness similarity cost function. Matching accuracy was evaluated using landmarks, vessel tree, and fissure planes. The Jacobian determinant of the transformation was used to reveal the deformation pattern of local parenchymal tissue. The average matching error for intensity-only registration methods was on the order of 1 mm at landmarks and 1.5 mm on fissure planes. After adding the vesselness preserving cost function, the landmark and fissure positioning errors decreased approximately by 25% and 30%, respectively. The vesselness cost function effectively helped improve the registration accuracy in regions near thoracic cage and near the diaphragm for all the intensity-only registration algorithms tested and also helped produce more consistent and more reliable patterns of regional tissue deformation.
منابع مشابه
Incorporating sheet-likeness information in intensity-based lung CT image registration
Image registration is a useful technique to measure the change between two or more images. Lung CT image registration is widely used an non-invasive method to measure the lung function changes. Non-invasive lung function measurement accuracy highly depends on lung CT image registration accuracy. Improving the registration accuracy is an important issue. In this thesis, we propose incorporating ...
متن کاملLung registration using automatically detected landmarks.
OBJECTIVES Accurate registration of lung CT images is inevitable for numerous clinical applications. Usually, nonlinear intensity-based methods are used. Their accuracy is typically evaluated using corresponding anatomical points (landmarks; e.g. bifurcations of bronchial and vessel trees) annotated by medical experts in the images to register. As image registration can be interpreted as corres...
متن کاملCurve- and Surface-based Registration of Lung CT images via Currents
Feature-based registration methods offer a robust alternative to intensity-based methods when intensities change because of pathology, image artifacts or differences in acquisition. For registration of lung CT images, we propose to use distinctive anatomical structures, such as the pulmonary vessel tree centerlines and lung surfaces, to establish correspondences between pairs of scans. In this ...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملCPOL: Complex phase order likelihood as a similarity measure for MR-CT registration
A novel similarity measure for registering magnetic resonance (MR) and computed tomography (CT) images has been designed and built. MR-CT registration methods often rely on the statistical intensity relationship between the images. The proposed similarity measure instead depends on the statistical relationship between the complex phase order between the images. By utilizing the complex phase or...