Missing wedge computed tomography by iterative algorithm DIRECTT.

نویسندگان

  • Andreas Kupsch
  • Axel Lange
  • Manfred P Hentschel
  • Sebastian Lück
  • Volker Schmidt
  • Roman Grothausmann
  • André Hilger
  • Ingo Manke
چکیده

A strategy to mitigate typical reconstruction artefacts in missing wedge computed tomography is presented. These artefacts appear as elongations of reconstructed details along the mean direction (i.e. the symmetry centre of the projections). Although absent in standard computed tomography applications, they are most prominent in advanced electron tomography and also in special topics of X-ray and neutron tomography under restricted geometric boundary conditions. We investigate the performance of the DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm to reduce the directional artefacts in standard procedures. In order to be sensitive to the anisotropic nature of missing wedge artefacts, we investigate isotropic substructures of metal foam as well as circular disc models. Comparison is drawn to filtered backprojection and algebraic techniques. Reference is made to reconstructions of complete data sets. For the purpose of assessing the reconstruction quality, Fourier transforms are employed to visualize the missing wedge directly. Deficient reconstructions of disc models are evaluated by a length-weighted kernel density estimation, which yields the probabilities of boundary orientations. The DIRECTT results are assessed at different signal-to-noise ratios by means of local and integral evaluation parameters.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reconstruction of Limited View Tomography Data by DIRECTT

Incomplete tomographic data sets such as limited view (missing wedge) data represent a well-known challenge for reconstruction algorithms, since they unavoidably lead to substantial image artefacts. Such data sets may occur in industrial computed tomography of limited access (e.g. extended components, fixed objects), directional opacity, limited sample life time or laminographic set-up. We pres...

متن کامل

Enhanced Spatial Resolution Using Iterative Focal Desmearing in Computed Tomography

Computed tomography reconstructions of projected data usually assume an ideal point-like focal spot. However, in practice, the actual finite focus size leads to blurred projections, unavoidably. The elements (voxels) of the reconstruction array are smeared differently as a function of their individual position relative to source and detector. Neglecting the focal smearing generates considerably...

متن کامل

Enhanced Spatial Resolution in 2D CT-Reconstruction without Filtered Back-Projection: DIRECTT

We report on novel developments of the DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm. Details are discussed for model calculations in order to elucidate its universal character for parallel and fan beam geometry. Our approach represents a promising alternative to the conventional filtered back-projection (FP). Instead of Fourier transforming single proj...

متن کامل

True 3D-CT-reconstruction in comparison to the FDK-algorithm

As has already been shown with 2D-models DIRECTT (Direct iterative reconstruction of computed tomography trajectories) exceeds the spatial resolution of the classical filtered back projection. In this work the DIRECTT algorithm is extended towards cone-beam projection including iterative 3D reconstruction. The improved speed is still overcompensated by the large amount of reconstruction space a...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of microscopy

دوره 261 1  شماره 

صفحات  -

تاریخ انتشار 2015