High-resolution optical Doppler tomography for in vitro and in vivo fluid flow dynamics.

نویسندگان

  • Cheng-Jen Chang
  • Kuang-Hua Hou
چکیده

BACKGROUND The objective of our research was to use a noninvasive tomographic imaging technique with high spatial resolution (2-15 microm) to characterize and monitor fluid flow and the microvasculature in highly scattering biological tissues at user-specified discrete locations. METHODS The technique of optical Doppler tomography (ODT) combines laser Doppler flowmetry (LDF) with optical coherence tomography to obtain high-resolution tomographic velocity and structural images of static and moving constituents in highly scattering biological tissues. We present ODT structural and velocity images using in vitro turbid samples of a circular conduit infused with a suspension of polymer microspheres. At a thin rectangular cross-section of the conduit, the Intralipid flow was measured. Blood flow velocity was measured in vivo in the ear of rodent skin. RESULTS In first model, the ODT velocity images demonstrated beads near the center of the conduit moving faster than those near the circular wall. In the second model, the ODT velocity images indicated that laminar flow was fastest along the central axis of the conduit. Blood flow in 2 small veins with diameters of 70 and 40 microm, respectively, and an artery with diameter of 25 microm, was clearly identified in a rodent model. CONCLUSION In our preliminary in vitro and in vivo studies on turbid samples and model vasculatures, we determined that the application of ODT to characterize and image blood flow with high spatial resolution at discrete user-specified locations in highly scattering biological tissues is feasible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography.

We report the development of an optical technique for noninvasive imaging of in vivo blood flow dynamics and tissue structures with high spatial resolution (2-10 microm) in biological systems. The technique is based on optical Doppler tomography (ODT), which combines Doppler velocimetry with optical coherence tomography to measure blood flow velocity at discrete spatial locations. The exception...

متن کامل

Optical Doppler tomography: imaging in vivo blood flow dynamics following pharmacological intervention and photodynamic therapy.

A noninvasive optical technique has been developed for imaging in vivo blood flow dynamics and vessel structure with high spatial resolution. The technique is based on optical Doppler tomography, which combines Doppler velocimetry with optical coherence tomography to measure blood flow velocity at discrete spatial locations in turbid biological tissue. Applications of this technique for monitor...

متن کامل

Absolute Permeability Calculation by Direct Numerical Simulation in Porous Media

Simulating fluid flow at micro level is an ongoing problem. Simplified macroscopic flow models like Darcy’s law is unable to estimate fluid dynamic properties of porous media. The digital sample reconstruction by high resolution X-ray computed tomography scanning and fluid-dynamics simulation, together with the increasing power of super-computers, allow to carry out pore-scale simulations throu...

متن کامل

Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media.

An optical Doppler tomography (ODT) system that permits imaging of fluid flow velocity in highly scattering media is described. ODT combines Doppler velocimetry with the high spatial resolution of low-coherence optical interferometry to measure fluid flow velocity at discrete spatial locations. Tomographic imaging of particle flow velocity within a circular conduit submerged 1 mm below the surf...

متن کامل

Three-beam Doppler optical coherence tomography using a facet prism telescope and MEMS mirror for improved transversal resolution

An improved three-beam Doppler optical coherence tomography system was developed. It utilizes a custom-made three-facet prism telescope to improve the transversal resolution at the sample. Furthermore, a two-axis gimbal-less MEMS mirror is used to minimize off-pivot beam movement at the pupil of the eye, enabling circular scanning for in vivo retinal measurements. We demonstrate the system's ab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chang Gung medical journal

دوره 26 6  شماره 

صفحات  -

تاریخ انتشار 2003