Soft-tissue Artefact Assessment and Compensation in Hip Joint Kinematics Using Motion Capture Data and Ultrasound Depth Measurements
نویسندگان
چکیده
Accurate location of the hip joint centre is a necessary component in biomechanical human motion analysis to measure skeletal parameters and describe human motion. In human movement analysis, the hip joint centre can be estimated using functional methods based on the relative motion of the femur to pelvis measured using reflective markers attached to the skin surface. Determination of the hip joint centre by functional methods suffers inaccuracy due to the soft tissue artefact, which is the relative motion between the markers and bone. Therefore, one of the main objectives in human movement analysis is the assessment and correction of the soft tissue artefact. Various studies have described the movement of the soft tissue artefact and minimized it invasively. The goal of this study is to present a non-invasive method to assess and reduce the soft tissue artefact effects using optical motion capture data and tissue thickness from ultrasound measurements during flexion, extension, and abduction of the hip joint. Results showed that the displacement of markers is non-linear and larger in areas closer to the hip joint. It was also found that the marker displacements are dependent on the movement type, being relatively larger in flexion movement. This quantification of soft tissue artefacts was used as a basis for a correction procedure for hip joint centre and minimizing the soft tissue artefact effects. Results showed that our method reduces the error in the functional hip joint centre from 13.65-22.54 mm to 7.9-12.82 mm.
منابع مشابه
Quantification of Soft Tissue Artefacts Using Motion Capture Data and Ultrasound Depth Measurements
The centre of rotation of the hip joint is needed for an accurate simulation of the joint performance in many applications such as pre-operative planning simulation, human gait analysis, and hip joint disorders. In human movement analysis, the hip joint center can be estimated using a functional method based on the relative motion of the femur to pelvis measured using reflective markers attache...
متن کاملUse of Ultrasound with Motion Capture to Measure Bone Displacement during Movement Made for Functional Hip Joint Center Determination
Calculation of hip joint center (HJC) through functional methods with markers placed on skin around thigh and pelvis is a non-invasive method for estimating the center of rotation of a ball and socket joint by recording movements of femur relative to acetabulum. But the HJC through this process suffers from a welldocumented source of error known as soft tissue artifacts (STA) which is the major...
متن کاملStandardization proposal of soft tissue artefact description for data sharing in human motion measurements.
Soft tissue artefact (STA) represents one of the main obstacles for obtaining accurate and reliable skeletal kinematics from motion capture. Many studies have addressed this issue, yet there is no consensus on the best available bone pose estimator and the expected errors associated with relevant results. Furthermore, results obtained by different authors are difficult to compare due to the hig...
متن کاملNon-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity.
The soft-tissue interface between skin-mounted markers and the underlying bones poses a major limitation to accurate, non-invasive measurement of joint kinematics. The aim of this study was twofold: first, to quantify lower limb soft-tissue artifact in young healthy subjects during functional activity; and second, to determine the effect of soft-tissue artifact on the calculation of knee joint ...
متن کاملFunctional Estimate of the Hip Joint Centre Location: a Soft Tissue Deformation Model for Simulation Studies
Accuracy and robustness of the algorithms used to determine the location of centres of rotation from stereophotogrametric data depend on their capacity to deal with the artefacts due to soft tissue deformation (STD). When evaluating these algorithms using a mathematical simulation approach, only random errors have been used to corrupt marker trajectories. This study aimed at modelling STD as a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014