A Novel ImageJ Macro for Automated Cell Death Quantitation in the Retina.

نویسندگان

  • Daniel E Maidana
  • Pavlina Tsoka
  • Bo Tian
  • Bernard Dib
  • Hidetaka Matsumoto
  • Keiko Kataoka
  • Haijiang Lin
  • Joan W Miller
  • Demetrios G Vavvas
چکیده

PURPOSE TUNEL assay is widely used to evaluate cell death. Quantification of TUNEL-positive (TUNEL+) cells in tissue sections is usually performed manually, ideally by two masked observers. This process is time consuming, prone to measurement errors, and not entirely reproducible. In this paper, we describe an automated quantification approach to address these difficulties. METHODS We developed an ImageJ macro to quantitate cell death by TUNEL assay in retinal cross-section images. The script was coded using IJ1 programming language. To validate this tool, we selected a dataset of TUNEL assay digital images, calculated layer area and cell count manually (done by two observers), and compared measurements between observers and macro results. RESULTS The automated macro segmented outer nuclear layer (ONL) and inner nuclear layer (INL) successfully. Automated TUNEL+ cell counts were in-between counts of inexperienced and experienced observers. The intraobserver coefficient of variation (COV) ranged from 13.09% to 25.20%. The COV between both observers was 51.11 ± 25.83% for the ONL and 56.07 ± 24.03% for the INL. Comparing observers' results with macro results, COV was 23.37 ± 15.97% for the ONL and 23.44 ± 18.56% for the INL. CONCLUSIONS We developed and validated an ImageJ macro that can be used as an accurate and precise quantitative tool for retina researchers to achieve repeatable, unbiased, fast, and accurate cell death quantitation. We believe that this standardized measurement tool could be advantageous to compare results across different research groups, as it is freely available as open source.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Throughput Method for Automated Colony and Cell Counting by Digital Image Analysis Based on Edge Detection

Counting cells and colonies is an integral part of high-throughput screens and quantitative cellular assays. Due to its subjective and time-intensive nature, manual counting has hindered the adoption of cellular assays such as tumor spheroid formation in high-throughput screens. The objective of this study was to develop an automated method for quick and reliable counting of cells and colonies ...

متن کامل

Fine quantitation of novel trace taxans in suspension-cultured Corylus avellana L. cells by photo diode array HPLC technique.

Taxanes are widely known as great family of antitumor compounds. Identification of certain taxanes, particularly taxol, has opened new perspectives for further researches in plant and medical sciences. The aim of the present study was to manipulate chromatographic method in order to detect and quantified novel trace taxanes in suspension-cultured hazel (Corylus avellana L.) cells. A rapid growi...

متن کامل

Decision Support System for Age-Related Macular Degeneration Using Convolutional Neural Networks

Introduction: Age-related macular degeneration (AMD) is one of the major causes of visual loss among the elderly. It causes degeneration of cells in the macula. Early diagnosis can be helpful in preventing blindness. Drusen are the initial symptoms of AMD. Since drusen have a wide variety, locating them in screening images is difficult and time-consuming. An automated digital fundus photography...

متن کامل

Automated High-throughput Behavioral Analyses in Zebrafish Larvae

We have created a novel high-throughput imaging system for the analysis of behavior in 7-day-old zebrafish larvae in multi-lane plates. This system measures spontaneous behaviors and the response to an aversive stimulus, which is shown to the larvae via a PowerPoint presentation. The recorded images are analyzed with an ImageJ macro, which automatically splits the color channels, subtracts the ...

متن کامل

A Novel Method for Automated Estimation of Effective Parameters of Complex Auditory Brainstem Response: Adaptive Processing based on Correntropy Concept

Objectives: Automated Auditory Brainstem Responses (ABR) peak detection is a novel technique to facilitate the measurement of neural synchrony along the auditory pathway through the brainstem. Analyzing the location of the peaks in these signals and the time interval between them may be utilized either for analyzing the hearing process or detecting peripheral and central lesions in the human he...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 56 11  شماره 

صفحات  -

تاریخ انتشار 2015