An ultrasound system for combined cardiac imaging and Doppler blood flow measurement in man.
نویسندگان
چکیده
An ultrasound instrument has been developed that combines a real-time cross-sectional imaging system and a spectrum analyzer-based Doppler velocimeter. This combination allows the Doppler sample volume to be superimposed on the cross-sectional image of the heart so that the sample volume can be located accurately. The same 2.2 MHz transducer utilized for cross-sectional imaging is stopped mechanically and quickly switched to transmit and receive the Doppler ultrasound signal. Preliminary experience in 20 young and adult normal subjects indicates that it is possible to place the Doppler sample volume in the proximal main pulmonary artery at a point where the sound beam and blood flow stream are parallel. Measurement of the distance from transducer to the sample volume and the peak blood flow velocities in the main pulmonary artery of normal subjects indicates that these quantities are within the measurement capabilities of the system. The ultimate goal of this device is to make measurements of volume blood flow in man noninvasively.
منابع مشابه
Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملبرآورد سرعت موج پالس با استفاده از پارامترهای شریانی استخراج شده از تصاویر فراصوتی کاروتید
Background & Objective : Several indices have been introduced to estimate arterial stiffness that based on changes in brachial blood pressure. But because of the error resulted by the substitution of brachial blood pressure instead of the other central arteries, such as carotid, it will be very important to present elastic parameter based on the mechanical models without any emphasis on brach...
متن کاملDetermination of left ventricular volume in children: echocardiographic and angiographic comparisons.
velocity probe. Circulation 40: 603, 1969 15. Greenfield JC, Harley A, Thompson HK, Wallace AG: Pressure-flow studies in man during atrial fibrillation. J Clin Invest 47: 2411, 1968 16. Goldberg BB: Suprasternal ultrasonography. JAMA 215: 245, 1971 17. Bommer WJ, Miller LR, Mason DT, DeMaria AN: Enhancement of pulsed Doppler echocardiography in the evaluation of aortic valve disease by the deve...
متن کاملBlood oxygen flux estimation with a combined photoacoustic and high-frequency ultrasound microscopy system: a phantom study.
The metabolic rate of oxygen consumption, an important indicator of tissue metabolism, can be expressed as the change of net blood oxygen flux into and out of a tissue region per 100 g of tissue. In this work, we propose a photoacoustic and Doppler ultrasound method for imaging local blood oxygen flux of a single vessel. An imaging system for combined photoacoustic and high-frequency ultrasound...
متن کاملNon-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis
In this study, a method for non-invasive estimation of stress on the heart wall in the diastole phase is presented using ultrasound echocardiography and tissue Doppler imaging. The aim of this study was to evaluate the stress on the heart wall as a pre-diagnosis to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 57 5 شماره
صفحات -
تاریخ انتشار 1978