Comparison of Bruce treadmill exercise test protocols: is ramped Bruce equal or superior to standard bruce in producing clinically valid studies for patients presenting for evaluation of cardiac ischemia or arrhythmia with body mass index equal to or greater than 30?
نویسندگان
چکیده
UNLABELLED Clinically valid cardiac evaluation via treadmill stress testing requires patients to achieve specific target heart rates and to successfully complete the cardiac examination. METHODS A comparison of the standard Bruce protocol and the ramped Bruce protocol was performed using data collected over a 1-y period from a targeted patient population with a body mass index (BMI) equal to or greater than 30 to determine which treadmill protocol provided more successful examination results. RESULTS The functional capacity, metabolic equivalent units achieved, pressure rate product, and total time on the treadmill as measured for the obese patients were clinically valid and comparable to normal-weight and overweight patients (P < 0.001). Data gathered from each protocol demonstrated that the usage of the ramped Bruce protocol achieved more consistent results in comparison across all BMI groups in achieving 80%-85% of their age-predicted maximum heart rate. CONCLUSION This study did not adequately establish that the ramped Bruce protocol was superior to the standard Bruce protocol for the examination of patients with a BMI equal to or greater than 30.
منابع مشابه
Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]
Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...
متن کاملبررسی تغییرات الکتروکاردیوگرام و حداکثر اکسیژن مصرفی مردان فعال متعاقب مصرف کافئین با دستگاه Custo Diagnostic
Background: Caffeine is isolated Methyl-xanthine, Alkaloid stimulants and it is the most commonly used drug in the world. The present study was to investigate the effect of caffeine on VO2max and Electrocardiograph in active male of student college after Bruce exhaustive exercise. Methods: 9 male active aged 25 (mean 20.9±1.37 years, fat percent 11.21±3.79 percentage and BMI 23.49±1.69 kg/m2) ...
متن کاملApplication of Anatomical and Functional Modalities in Detection of Silent Myocardial Ischemia in Asymptomatic Diabetic Patients- A Review Article
Cardiovascular disease (CAD) screening in asymptomatic patients with diabetes mellitus is controversial. An exercise stress test is a safe and effective initial testing for Ischemic Heart Disease (IHD) screening. Treadmill stress test is not the best screening method for a particular patient who is not able to exercise, abnormal electrocardiogram (ECG) or positive exercise treadmill test (ETT) ...
متن کاملارتباط نمایه توده بدنی با تست ورزش مختل در افراد با دردهای ایسکمیک قلبی
Background and purpose: Prevalence of over weight and obesity is increasing in the world. Those over weight are more susceptible to cardiovascular diseases than other individual's. Studies indicate that body fat distribution has a determining role in the identification of risk factors. Also, the relation between BMI, cardiac ischemic pains and exercise test condition in such patients, is in n...
متن کاملThe Effect of leech therapy on Blood Lactate Level and Pain Perception Index in Athletes following an Exhausting Physical Activity
Background & Aim: Leech Therapy is a type of complementary and alternative medicine that has been used for a long time as a therapeutic method in traditional Iranian Islamic medicine. The purpose of this study was to investigate the effect of leech therapy on blood lactate level and pain perception index following an Exhausting Physical activity in young male athletes. Methods: Sixteen athlete...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine technology
دوره 41 4 شماره
صفحات -
تاریخ انتشار 2013