Electrical Detection of Nucleic Acid Amplification Using an On-Chip Quasi-Reference Electrode and a PVC REFET

نویسندگان

  • Eric Salm
  • Yu Zhong
  • Bobby Reddy
  • Carlos Duarte-Guevara
  • Vikhram Swaminathan
  • Yi-Shao Liu
  • Rashid Bashir
چکیده

Electrical detection of nucleic acid amplification through pH changes associated with nucleotide addition enables miniaturization, greater portability of testing apparatus, and reduced costs. However, current ion-sensitive field effect transistor methods for sensing nucleic acid amplification rely on establishing the fluid gate potential with a bulky, difficult to microfabricate reference electrode that limits the potential for massively parallel reaction detection. Here we demonstrate a novel method of utilizing a microfabricated solid-state quasi-reference electrode (QRE) paired with a pH-insensitive reference field effect transistor (REFET) for detection of real-time pH changes. The end result is a 0.18 μm, silicon-on-insulator, foundry-fabricated sensor that utilizes a platinum QRE to establish a pH-sensitive fluid gate potential and a PVC membrane REFET to enable pH detection of loop mediated isothermal amplification (LAMP). This technique is highly amendable to commercial scale-up, reduces the packaging and fabrication requirements for ISFET pH detection, and enables massively parallel droplet interrogation for applications, such as monitoring reaction progression in digital PCR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of a PVC Membrane for Reference Field Effect Transistors

For the miniaturization of ISFET sensing systems, the concept of a REFET with low ion sensitivity is proposed to replace the conventional reference electrodes through the arrangement of a quasi reference electrode and a differential readout circuit. In this study, an ion-unblocking membrane was used as the top layer of a REFET. To optimize the REFET performance, the influences of the silylating...

متن کامل

Sensitivity and Specificity of Nucleic Acid Sequence-Based Amplification Method for Diagnosis of Cutaneous Leishmaniasis

Abstract Background and Objective: Culture, microscopic method is a gold standard method for identification of Lishmania parasite. The use of Molecular methods such as RT- PCR compared to microscopic methods has a higher sensitivity and specificity however, it is not widely used due to its expensive equipment and the time requested. The use of nucleic acid sequence based amplification (NASBA) ...

متن کامل

Evaluation of Nucleic Acid Sequence Based Amplification (NASBA) and Reverse Transcription Polymerase Chain Reaction for Detection of Coxsackievirus B3 in Cell Culture and Animal Tissue Samples

Enteroviruses are the causative agents of a number of diseases in humans. Group B coxsackieviruses are believed to be the most common viral agents responsible for human heart disease. Genomic data of enteroviruses has allowed developing new molecular approaches such as Nucleic Acid Sequence Based Amplification (NASBA) for detection of such viruses. In this study, coxsackievirus B3 (CVB3) was de...

متن کامل

Designing a Label Free Aptasensor for Detection of Methamphetamine

A label-free electrochemical nucleic acid aptasensor for the detection of methamphetamine (MA) by the immobilization of thiolated self-assembled DNA sequences on a gold nanoparticles-chitosan modified electrode is constructed. When MA was complexed specifically to the aptamer, the configuration of the nucleic acid aptamer switched to a locked structure and the interface of the biosensor changed...

متن کامل

Application of a dioxime-PVC electrode to potentiometric studies of Cr(III) ion

A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 86  شماره 

صفحات  -

تاریخ انتشار 2014