Regression algorithm correcting for partial volume effects in arterial spin labeling MRI.
نویسندگان
چکیده
Partial volume effects (PVE) are a consequence of limited spatial resolution in brain imaging. In arterial spin labeling (ASL) MRI, the problem is exacerbated by the nonlinear dependency of the ASL signal on magnetization contributions from each tissue within an imaged voxel. We have developed an algorithm that corrects for PVE in ASL imaging. The algorithm is based on a model that represents the voxel intensity as a weighted sum of pure tissue contribution, where the weighting coefficients are the tissue's fractional volume in the voxel. Using this algorithm, we were able to estimate cerebral blood flow (CBF) for gray matter (GM) and white matter (WM) independently. The average voxelwise ratio of GM to WM CBF was approximately 3.2, in good agreement with reports in the literature. As proof of concept, data from PVE-corrected method were compared with those from the conventional, PVE-uncorrected method. As hypothesized, the two yielded similar CBF values for voxels containing >95% GM and differed in proportion with the voxels' heterogeneity. More importantly, the GM CBF assessed with the PVE-corrected method was independent of the voxels' heterogeneity, implying that estimation of flow was unaffected by PVE. An example of application of this algorithm in motor-activation data is also given.
منابع مشابه
Validation of diffuse correlation spectroscopy measurements of rodent cerebral blood flow with simultaneous arterial spin labeling MRI; towards MRI-optical continuous cerebral metabolic monitoring
Cerebral blood flow (CBF) during stepped hypercapnia was measured simultaneously in the rat brain using near-infrared diffuse correlation spectroscopy (DCS) and arterial spin labeling MRI (ASL). DCS and ASL CBF values agree very well, with high correlation (R=0.86, p< 10(-9)), even when physiological instability perturbed the vascular response. A partial volume effect was evident in the smaller...
متن کاملPartial volume correction of brain perfusion estimates using the inherent signal data of time-resolved arterial spin labeling.
Quantitative perfusion MRI based on arterial spin labeling (ASL) is hampered by partial volume effects (PVEs), arising due to voxel signal cross-contamination between different compartments. To address this issue, several partial volume correction (PVC) methods have been presented. Most previous methods rely on segmentation of a high-resolution T1 -weighted morphological image volume that is co...
متن کاملMapping cerebrovascular reactivity using blood oxygen level-dependent MRI in Patients with arterial steno-occlusive disease: comparison with arterial spin labeling MRI.
BACKGROUND AND PURPOSE Blood oxygen level-dependent MRI (BOLD MRI) of hypercapnia-induced changes in cerebral blood flow is an emerging technique for mapping cerebrovascular reactivity (CVR). BOLD MRI signal reflects cerebral blood flow, but also depends on cerebral blood volume, cerebral metabolic rate, arterial oxygenation, and hematocrit. The purpose of this study was to determine whether, i...
متن کاملAnteroposterior perfusion heterogeneity in human hippocampus measured by arterial spin labeling MRI.
Measurements of blood flow in the human hippocampus are complicated by its relatively small size, unusual anatomy and patterns of blood supply. Only a handful of arterial spin labeling (ASL) MRI articles have reported regional cerebral blood flow (rCBF) values for the human hippocampus. Numerous reports have found heterogeneity in a number of other physiological and biochemical parameters along...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 60 6 شماره
صفحات -
تاریخ انتشار 2008