Diagnostic accuracy of conventional radiography and digital radiography in detecting of root fractures (invitro study)

نویسندگان

  • Amin-Tavakoli M.
  • Amin Tavakoli
چکیده

Purpose: Root fracture is a clinical problem which often is difficult to detect and diagnose. As the root fracture detection is based on demonstration of a fracture line or lines, radiographic examination is important. The aim of this study was to compare diagnostic efficacy of direct digital radiography with conventional radiography for detecting experimental root fractures. Materials & Methods: This study was based on observational diagnostic method which eighty one extracted single rooted human teeth were endodontically instrumented and divided into two groups, a control group of 40 teeth and a fractured group of 41 teeth in which root fractures were produced with Instron machine. Each tooth was imaged using the parallel technique with a CCD-based digital system and E-speed film. The images were interpreted by three experienced oral and maxillofacial radiologists without prior knowledge of the distribution of the root fractures. Three image groups were taken: conventional film, digital images and enhanced digital images. Sensitivity, specificity, false negative and false positive percentage, accuracy of each method in comparison with golden standard (visual examination of fractured and intact teeth) were analyzed. The degree of agreement in detecting root fractures with each imaging system compared with each other was expressed as the kappa value. Results: The sensitivity, specificity and accuracy for root fractures in conventional radiography were 73.2%, 87.5% and 80.2% respectively, in direct digital radiography were 78%, 77.5% and 77.8% respectively and in enhanced direct digital radiography were 82.9%, 85% and 84% respectively. The most sensitive was enhanced direct digital radiography and the most specific was conventional radiography. There was fair to good agreement between conventional radiography and digital radiography (k=0.68), fair to good agreement between enhanced digital radiography and conventional radiography (k=0.73) and excellent agreement between digital radiography and enhanced digital radiography (k=0.90). Conclusions: The diagnostic efficacy of Conventional radiography, digital radiography and enhanced digital radiography in detecting root fractures was comparable with each other. _______________________________________________________________________________

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Comparison of the Diagnostic Accuracy of Digital Intraoral Radiography with PSP and CBCT in the Detection of Horizontal and Vertical Dental Root Fractures

Background and Aim: Clinical and radiographic diagnoses of dental root fractures have always been difficult and require high accuracy in dental care and treatment. The aim of this study was to compare the diagnostic accuracy of intraoral digital radiography (PSP) and CBCT in the detection of horizontal and vertical root fractures (HRF and VRF). Materials and Methods: For this experimental stud...

متن کامل

Comparison of Accuracy and Observer Agreement in the Detection of Simulated External Root Resorption Using Conventional Digital Radiography and Digitally Filtered Radiography

Introduction: External root resorption is a clinical problem that often cannot be detected clinically. Thus, radiography plays a crucial role in its diagnosis. However, optimal radiographic quality with minimal radiation exposure {2.1 [EN] Verify English word/phrase choice} is an important factor in selecting the appropriate radiographic technique. The aim of this study was the comparison of ac...

متن کامل

The Effect of Intra-Canal Posts on Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography in Detection of Vertical Root Fractures

Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics. Cone Beam Computed Tomography (CBCT)  has significantly enhanced image quality compared to digital radiography (DR) and greatly aids the diagnosis of VRFs but, metal artifacts has remained as a problem in VRF detection.  This study evaluated the effect of intra canal posts on the diagnostic accuracy of CBCT and D...

متن کامل

A Comparative Study of Diagnostic Accuracy of Cone Beam Computed Tomography and Intra Oral Digital Radiography Phosphor Storage Plates in Detecting Strip Perforation in Endodontically-Treated Teeth

Background and purpose: Perforation impairs the prognosis of endodontic treatments, so, timely and accurate diagnosis is important. For this purpose, various radiographic diagnostic tools have been studied to select the method that has the least complications and helps in making the most accurate diagnosis. This study aimed to compare the accuracy of cone beam computed tomography (CBCT) and int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005