Dosimetric comparison study between intensity modulated radiation therapy and three‐dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer

نویسندگان

  • William Y. Song
  • Soon N. Huh
  • Yun Liang
  • Greg White
  • R. Charles Nichols
  • W. Tyler Watkins
  • Arno J. Mundt
  • Loren K. Mell
چکیده

The objective was to compare intensity-modulated radiation therapy (IMRT) with 3D conformal proton therapy (3DCPT) in the treatment of cervical cancer. In particular, each technique's ability to spare pelvic bone marrow (PBM) was of primary interest in this study. A total of six cervical cancer patients (3 postoperative and 3 intact) were planned and analyzed. All plans had uniform 1.0 cm CTV-PTV margin and satisfied the 95% PTV with 100% isodose (prescription dose = 45 Gy) coverage. Dose-volume histograms (DVH) were analyzed for comparison. The overall PTV and PBM volumes were 1035.9 ± 192.2 cc and 1151.4 ± 198.3 cc, respectively. In terms of PTV dose conformity index (DCI) and dose homogeneity index (DHI), 3DCPT was slightly superior to IMRT with 1.00 ± 0.001, 1.01 ± 0.02, and 1.10 ± 0.02, 1.13 ± 0.01, respectively. In addition, 3DCPT demonstrated superiority in reducing lower doses (i.e., V30 or less) to PBM, small bowel and bladder. Particularly in PBM, average V10 and V20 reductions of 10.8% and 7.4% (p = 0.001 and 0.04), respectively, were observed. However, in the higher dose range, IMRT provided better sparing (> V30). For example, in small bowel and PBM, average reductions in V45 of 4.9% and 10.0% (p = 0.048 and 0.008), respectively, were observed. Due to its physical characteristics such as low entrance dose, spread-out Bragg peak and finite particle range of protons, 3DCPT illustrated superior target coverage uniformity and sparing of the lower doses in PBM and other organs. Further studies are, however, needed to fully exploit the benefits of protons for general use in cervical cancer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.

Introduction:   The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer.   Materials and Methods:   Two CT scan was performred for each pati...

متن کامل

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010