Immobilization and voltammetric detection of human interleukine-2 gene on the pencil graphite electrode.
نویسندگان
چکیده
The immobilization and differential pulse anodic voltammetry (DPAV) of a 20-mer oligonucleotide related to the human interleukine-2 (hIL-2) using renewable pencil graphite electrode (PGE) is described. The influences of electrochemical pretreatment of PGE on the ability of the electrode in hIL-2 adsorption, and conditions of hiIL-2 immobilization on PGE including immobilization potential and time, sodium chloride concentration as well as stirring of the solution were studied and optimum conditions were suggested. Accordingly, the electrochemical pretreatment of the polished PGE by electrostatic procedure at 1.80V for 5min in 0.50M acetate buffer solution of pH 4.8 is proposed as the optimum pre-treatment procedure. Similarly, the obtained optimum conditions for immobilization of hIL-2 on the activated PGE was an immobilization duration of 5min at applied potential of 0.50V. Trace levels of hIL-2 was readily detected following only 5min immobilization period with detection limit of 6nM.
منابع مشابه
Electrochemical Detection of Insulin in Blood serum using Ppy/GF Nanocomposite Modified Pencil Graphite Electrode
In this study, pencil graphite electrode was modified using conductive polypyrrole (Ppy) and grapheme (GF) nanocomposite for electrochemical determination of insulin. Electrochemical behavior of insulin on PGE was investigated using cyclic voltammetric (CV) and differential pulse voltammetric (DPV) and chronoaprometry (CA) methods. Several effective parameters including pH, concentration, and s...
متن کاملElectrochemical Behavior of 2-Aminothiazole at Poly Glycine Modified Pencil Graphite Electrode
Electro analysis of 2-Aminothiazole (2-AT) by a low cost poly Glycine modified Pencil Graphite Electrode (poly Gly/PGE) was studied using of cyclic voltammetric (CV) and differential pulse voltammetric (DPV) techniques. The optimal experimental conditions to determine 2-AT was setup by the variation of the current with scan rate, concentration and pH. Electrochemical performance of the 2-AT at ...
متن کاملDeveloping an electrochemical deoxyribonucleic acid (DNA) biosensor on the basis of human interleukine-2 gene using an electroactive label.
Development of an electrochemical DNA biosensor based on a human interleukine-2 (IL-2) gene probe, using a pencil graphite electrode (PGE) as transducer and methylene blue (MB) as electroactive label is described. The sensor relies on the immobilization of a 20-mer single stranded oligonucleotide probe (hIL-2) related to the IL-2 gene on the electrode. The hybridization between the probe and it...
متن کاملFabrication of a Voltammetric Biosensor in Combination with Enzyme-linked Immunosorbent Assay to Detect Aflatoxin M1 in Milks
Background and Objectives: Aflatoxin M1 is one the most important mycotoxin contaminants of milks. Various methods have been described to detect aflatoxins in milks, including chromatography, enzyme-linked immunosorbent assay and colorimetry. Regarding high sensitivity of electrochemical sensor based methods, the aim of the present study was to fabricate an accurate sensitive voltametric biosen...
متن کاملLabel-Free Electrochemical Detection of the Specific Oligonucleotide Sequence of Dengue Virus Type 1 on Pencil Graphite Electrodes
A biosensor that relies on the adsorption immobilization of the 18-mer single-stranded nucleic acid related to dengue virus gene 1 on activated pencil graphite was developed. Hybridization between the probe and its complementary oligonucleotides (the target) was investigated by monitoring guanine oxidation by differential pulse voltammetry (DPV). The pencil graphite electrode was made of ordina...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Talanta
دوره 71 4 شماره
صفحات -
تاریخ انتشار 2007