On residual dose rate within particle accelerator enclosures.

نویسنده

  • J D Cossairt
چکیده

A mathematical proof of a theorem concerning the flux density of particles at any point interior to a simple closed convex surface in which the surface emits such particles uniformly and isotropically is presented. The relationship of this theorem, which is of rather general validity, to related observations of other workers is discussed. The ramifications of the theorem are considered with particular attention devoted to conditions commonly found at particle accelerators. It is concluded that results of this theorem are directly applicable to efforts to apply the principle of maintaining dose equivalents received by personnel as low as reasonably achievable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced-technology radiation therapy in the management of bone and soft tissue sarcomas.

BACKGROUND For patients with sarcomas, radiotherapy can be used as neoadjuvant, adjuvant, or primary local therapy, depending on the site and type of sarcoma, the surgical approach, and the efficacy of chemotherapy. METHODS The authors review the current status of advanced technology radiation therapy in the management of bone and soft tissue sarcoma. RESULTS Advances in radiotherapy have r...

متن کامل

Monte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy

Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...

متن کامل

Multiple-source models for electron beams of a medical linear accelerator using BEAMDP computer code.

AIM The aim of this work was to develop multiple-source models for electron beams of the NEPTUN 10PC medical linear accelerator using the BEAMDP computer code. BACKGROUND One of the most accurate techniques of radiotherapy dose calculation is the Monte Carlo (MC) simulation of radiation transport, which requires detailed information of the beam in the form of a phase-space file. The computing...

متن کامل

A single-source photon source model of a linear accelerator for Monte Carlo dose calculation

PURPOSE To introduce a new method of deriving a virtual source model (VSM) of a linear accelerator photon beam from a phase space file (PSF) for Monte Carlo (MC) dose calculation. MATERIALS AND METHODS A PSF of a 6 MV photon beam was generated by simulating the interactions of primary electrons with the relevant geometries of a Synergy linear accelerator (Elekta AB, Stockholm, Sweden) and rec...

متن کامل

Persistence and biodegradation of kerosene in high-arctic intertidal sediment.

A kerosene type hydrocarbon fraction (equivalent to 7 L m(-2)) was added to enclosures in the surface layer of high-arctic intertidal beach sediment. The experimental spill was repeated in two consecutive years in the period July-September. The rate and extent of hydrocarbon removal and the accompanying bacterial response were monitored for 79 days (2002) and 78 days (2003). The bulk of added k...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Health physics

دوره 71 3  شماره 

صفحات  -

تاریخ انتشار 1996