Study of Optimal Perimetric Testing in Children (OPTIC): Feasibility, Reliability and Repeatability of Perimetry in Children

نویسندگان

  • Dipesh E. Patel
  • Phillippa M. Cumberland
  • Bronwen C. Walters
  • Isabelle Russell-Eggitt
  • Jugnoo S. Rahi
  • Benjamin Thompson
چکیده

PURPOSE To investigate feasibility, reliability and repeatability of perimetry in children. METHODS A prospective, observational study recruiting 154 children aged 5-15 years, without an ophthalmic condition that affects the visual field (controls), identified consecutively between May 2012 and November 2013 from hospital eye clinics. Perimetry was undertaken in a single sitting, with standardised protocols, in a randomised order using the Humphrey static (SITA 24-2 FAST), Goldmann and Octopus kinetic perimeters. Data collected included test duration, subjective experience and test quality (incorporating examiner ratings on comprehension of instructions, fatigue, response to visual and auditory stimuli, concentration and co-operation) to assess feasibility and reliability. Testing was repeated within 6 months to assess repeatability. RESULTS Overall feasibility was very high (Goldmann=96.1%, Octopus=89% and Humphrey=100% completed the tests). Examiner rated reliability was 'good' in 125 (81.2%) children for Goldmann, 100 (64.9%) for Octopus and 98 (63.6%) for Humphrey perimetry. Goldmann perimetry was the most reliable method in children under 9 years of age. Reliability improved with increasing age (multinomial logistic regression (Goldmann, Octopus and Humphrey), p<0.001). No significant differences were found for any of the three test strategies when examining initial and follow-up data outputs (Bland-Altman plots, n=43), suggesting good test repeatability, although the sample size may preclude detection of a small learning effect. CONCLUSIONS Feasibility and reliability of formal perimetry in children improves with age. By the age of 9 years, all the strategies used here were highly feasible and reliable. Clinical assessment of the visual field is achievable in children as young as 5 years, and should be considered where visual field loss is suspected. Since Goldmann perimetry is the most effective strategy in children aged 5-8 years and this perimeter is no longer available, further research is required on a suitable alternative for this age group.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Optimal Perimetric Testing In Children (OPTIC): development and feasibility of the kinetic perimetry reliability measure (KPRM).

INTRODUCTION Interpretation of perimetric findings, particularly in children, relies on accurate assessment of test reliability, yet no objective measures of reliability exist for kinetic perimetry. We developed the kinetic perimetry reliability measure (KPRM), a quantitative measure of perimetric test reproducibility/reliability and report here its feasibility and association with subjective a...

متن کامل

Study of Optimal Perimetric Testing In Children (OPTIC): Normative Visual Field Values in Children.

PURPOSE We sought to define normative visual field (VF) values for children using common clinical test protocols for kinetic and static perimetry. DESIGN Prospective, observational study. SUBJECTS We recruited 154 children aged 5 to 15 years without any ophthalmic condition that would affect the VF (controls) from pediatric clinics at Moorfields Eye Hospital. METHODS Children performed pe...

متن کامل

Feasibility, Accuracy, and Repeatability of Suprathreshold Saccadic Vector Optokinetic Perimetry

PURPOSE To evaluate feasibility, accuracy, and repeatability of suprathreshold Saccadic Vector Optokinetic Perimetry (SVOP) by comparison with Humphrey Field Analyzer (HFA) perimetry. METHODS The subjects included children with suspected field defects (n = 10, age 5-15 years), adults with field defects (n = 33, age 39-78 years), healthy children (n = 12, age 6-14 years), and healthy adults (n...

متن کامل

A Comparison of Perimetric Results from a Tablet Perimeter and Humphrey Field Analyzer in Glaucoma Patients

PURPOSE To determine the correlation between the perimetric outcomes from perimetry software Melbourne Rapid Fields (MRF) run on an Apple iPad tablet and those from the Humphrey Field Analyzer (HFA). METHODS The MRF software was designed with features including variable fixation and fast thresholding using Bayes logic. Here, we report a cross-sectional study on 90 eyes from 90 participants: 1...

متن کامل

Diagnostic Performance and Repeatability of a Novel Game-Based Visual Field Test for Children.

Purpose To demonstrate utility of a game-based test ("Caspar's Castle") for the detection of visual field defects in children. Methods A validity and reliability study was carried out at Manchester Royal Eye Hospital Pediatric Ophthalmology Outpatients Department. We recruited 108 children with no eye pathology (aged 4-12 years) and examined a single eye with the Caspar's Castle system using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015