Comparing HILIC and RPLC of Morphine Using Agilent ZORBAX RRHD Columns with UHPLC/MS
نویسنده
چکیده
UHPLC/MS analyses of morphine and 3 of its metabolites (normorphine, morphine3-b-D-glucuronide [M3G], and morphine-6-b-D-glucuronide [M6G]) are used to compare mass spectrometer sensitivity with reversed-phase liquid chromatography (RPLC) and hydrophilic interaction chromatography (HILIC). Two Agilent ZORBAX Rapid Resolution High Definition (RRHD) columns are used in this comparison, an Agilent ZORBAX RRHD Eclipse Plus C18 for the RPLC method and an Agilent ZORBAX RRHD HILIC Plus for the HILIC method. Each is used with an Agilent 1290 Infinity LC System with an Agilent 6410A Triple Quadrupole Mass Spectrometer. Both methods use isocratic elution with an acetonitrile/ammonium acetate buffer mobile phase. Signal-to-noise calculations for the least sensitive M6G peak show HILIC mode allows for more sensitive MS detection due to more efficient spraying and desolvation in the ESI-MS source, as a result of the volatile acetonitrile rich mobile phase used.
منابع مشابه
Rapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column Authors
An Agilent ZORBAX sub-2 μm Rapid Resolution High Definition (RRHD) 300SB-C8 reversed-phase column was used under optimized chromatographic conditions for delivering highly resolved ultra fast separations of reduced and alkylated monoclonal antibodies. The StableBond C8 phase and RRHD column technology, in combination with robust gradient elution conditions enabled efficient, fast, and effective...
متن کاملOptimized Analytical Procedures for the Untargeted Metabolomic Profiling of Human Urine and Plasma by Combining Hydrophilic Interaction (HILIC) and Reverse-Phase Liquid Chromatography (RPLC)–Mass Spectrometry*
Profiling of body fluids is crucial for monitoring and discovering metabolic markers of health and disease and for providing insights into human physiology. Since human urine and plasma each contain an extreme diversity of metabolites, a single liquid chromatographic system when coupled to mass spectrometry (MS) is not sufficient to achieve reasonable metabolome coverage. Hydrophilic interactio...
متن کاملAnalysis of Potential Genotoxic Arylamine and Aminopyridine Impurities in Active Pharmaceutical Ingredients Agilent 1290 Infinity LC system and Agilent 6460A Triple Quadrupole MS system for method development and fast analysis
This Application Note illustrates the possibilities of the Agilent 1290 Infinity LC system and the Agilent 6460A Triple Quadrupole Mass Spectrometer for quantitative analysis of potential genotoxic impurities (PGIs) in active pharmaceutical ingredients (APIs). A generic approach was used to determine arylamine and aminopyridine PGIs in selected APIs. The influence of column length and mobile ph...
متن کاملAnalysis of Polar Compounds Using 100% Aqueous Mobile Phases with Agilent ZORBAX Eclipse Plus Phenyl-Hexyl and Other ZORBAX Phenyl Columns
The analysis of polar compounds, such as acids and bases, typically requires ion pairing reagents or Hydrophobic Interaction Chromatography (HILIC) columns in HPLC. In this work, the utility of phenyl columns is demonstrated using 100% aqueous mobile phase, without the inconvenience of phase collapse. Selectivity of different Agilent ZORBAX phenyl phases (StableBond SB-Phenyl, Eclipse XDB-Pheny...
متن کاملRecent advances in application of hydrophilic interaction chromatography for quantitative bioanalysis.
Hydrophilic interaction chromatography (HILIC) provides a complementary separation mode to RPLC and thus has been gaining increased utilization in LC-MS/MS based quantitative bioanalysis. It has proven to be a powerful tool for separation of polar compounds and has afforded increased selectivity, higher sensitivity, and improved efficiency for quantitation of drug and their metabolites in compl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012