Quad-barrel multifunctional electrochemical and ion conductance probe for voltammetric analysis and imaging.

نویسندگان

  • Binoy Paulose Nadappuram
  • Kim McKelvey
  • Joshua C Byers
  • Aleix G Güell
  • Alex W Colburn
  • Robert A Lazenby
  • Patrick R Unwin
چکیده

The fabrication and use of a multifunctional electrochemical probe incorporating two independent carbon working electrodes and two electrolyte-filled barrels, equipped with quasi-reference counter electrodes (QRCEs), in the end of a tapered micrometer-scale pipet is described. This "quad-probe" (4-channel probe) was fabricated by depositing carbon pyrolytically into two diagonally opposite barrels of a laser-pulled quartz quadruple-barrelled pipet. After filling the open channels with electrolyte solution, a meniscus forms at the end of the probe and covers the two working electrodes. The two carbon electrodes can be used to drive local electrochemical reactions within the meniscus while a bias between the QRCEs in the electrolyte channels provides an ion conductance signal that is used to control and position the meniscus on a surface of interest. When brought into contact with a surface, localized high resolution amperometric imaging can be achieved with the two carbon working electrodes with a spatial resolution defined by the meniscus contact area. The substrate can be an insulating material or (semi)conductor, but herein, we focus mainly on conducting substrates that can be connected as a third working electrode. Studies using both aqueous and ionic liquid electrolytes in the probe, together with gold and individual single walled carbon nanotube samples, demonstrate the utility of the technique. Substrate generation-dual tip collection measurements are shown to be characterized by high collection efficiencies (approaching 100%). This hybrid configuration of scanning electrochemical microscopy (SECM) and scanning electrochemical cell microscopy (SECCM) should be powerful for future applications in electrode mapping, as well as in studies of insulating materials as demonstrated by transient spot redox-titration measurements at an electrostatically charged Teflon surface and at a pristine calcite surface, where a functionalized probe is used to follow the immediate pH change due to dissolution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scanning electrochemical microscopy. 32. Gallium ultramicroelectrodes and their application in ion-selective probes.

Gallium ultramicroelectrodes for amperometric measurements in scanning electrochemical microscopy were fabricated by introduction of liquid Ga into drawn glass micropipets. Cyclic voltammetry of Ru(NH(3))(6)(3+) and the use of this species for SECM imaging is described. Double-barrel micropipet tips with a Ga amperometric electrode and an ion-selective (K(+)) potentiometric probe can also be co...

متن کامل

Study and optimization of the necessary conditions for the sensitive determination of the lead ion by a modified carbon paste electrode in environmental water samples

Rapid and facile preparation of the cheap modified electrode materials is an important parameter in development of the efficient electrochemical sensor for industrial scale production and mass-market usage. In the present work, the carbon paste electrode modified with multi-walled carbon nanotubes (MWCNTs) was prepared for sensitive determination of lead (Pb) ion in the presence of bismuth (Bi)...

متن کامل

Study and optimization of the necessary conditions for the sensitive determination of the lead ion by a modified carbon paste electrode in environmental water samples

Rapid and facile preparation of the cheap modified electrode materials is an important parameter in development of the efficient electrochemical sensor for industrial scale production and mass-market usage. In the present work, the carbon paste electrode modified with multi-walled carbon nanotubes (MWCNTs) was prepared for sensitive determination of lead (Pb) ion in the presence of bismuth (Bi)...

متن کامل

Fabrication and characterization of dual function nanoscale pH-scanning ion conductance microscopy (SICM) probes for high resolution pH mapping.

The easy fabrication and use of nanoscale dual function pH-scanning ion conductance microscopy (SICM) probes is reported. These probes incorporate an iridium oxide coated carbon electrode for pH measurement and an SICM barrel for distance control, enabling simultaneous pH and topography mapping. These pH-SICM probes were fabricated rapidly from laser pulled theta quartz pipets, with the pH elec...

متن کامل

An Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions

In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 87 7  شماره 

صفحات  -

تاریخ انتشار 2015