Recovery of Slice Rotations with the Stack Alignment Transform in Cardiac MR Series

نویسندگان

  • Constantine Zakkaroff
  • Aleksandra Radjenovic
  • John P. Greenwood
  • Derek R. Magee
چکیده

Constantine Zakkaroff1 [email protected] Aleksandra Radjenovic2 [email protected] John P. Greenwood3 [email protected] Derek R. Magee1 [email protected] 1 School of Computing University of Leeds, UK 2 National Institute for Health Research, Leeds Musculoskeletal Biomedical Research Unit University of Leeds, UK 3 Leeds Institute of Genetics, Health and Therapeutics University of Leeds, UK

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stack Alignment Transform for Misalignment Correction in Cardiac MR Cine Series

Stack misalignment in cardiac MR cine series distorts the correct appearance of anatomical features and reduces the reproducibility of volumetric measurements computed for diagnostic purposes. This paper describes a method for correction of stack misalignment in cardiac MR series. Our method involves registration against a reference volume and features a prominent enhancement designed to circum...

متن کامل

Optimized co-registration method of Spinal cord MR Neuroimaging data analysis and application for generating multi-parameter maps

Introduction: The purpose of multimodal and co-registration In MR Neuroimaging is to fuse two or more sets images (T1, T2, fMRI, DTI, pMRI, …) for combining the different information into a composite correlated data set in order to visualization, re-alignment and generating transform to functional Matrix. Multimodal registration and motion correction in spinal cord MR Neuroimag...

متن کامل

Performance Analysis of Distance Transform Based Inter- Slice Similarity Information on Segmentation of Medical Image Series

Segmentation of organs from CT and MR image series is a challenging research area in all fields of medical imaging. Although, organs of interest are threedimensional in nature, slice-by-slice approaches are widely used in clinical applications because of their ease of integration with the current manual segmentation scheme (i.e. gold standard). Moreover, the high anisotropy of CT and MR data ma...

متن کامل

Improvement of knowledge-based automatic slice-alignment method for cardiac magnetic resonance imaging

Background Automatic slice alignment allows images of the six standard cardiac planes as defined in the SCMR Image Acquisition Protocols to be obtained by simple and quick operation. Our previously reported method can detect these planes using ECG-gated breath-hold axial multislice images [1]. Achieving higher accuracy and greater robustness for variation in clinical images will lead to improve...

متن کامل

A stack-based chaotic algorithm for encryption of colored images

In this paper, a new method is presented for encryption of colored images. This method is based on using stack data structure and chaos which make the image encryption algorithm more efficient and robust. In the proposed algorithm, a series of data whose range is between 0 and 3 is generated using chaotic logistic system. Then, the original image is divided into four subimages, and these four i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012