Measurement of Indocyanine Green dye is improved by use of polyethylene glycol to reduce plasma turbidity.

نویسندگان

  • M J Luetkemeier
  • J A Fattor
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total bilirubin measurement by photometry on a blood gas analyzer: potential for use in neonatal testing at the point of care.

The results are summarized in Table 1. The baseline absorbance of untreated plasma samples was significantly higher (0.106 6 0.076) than that of plasma samples treated with PEG (0.007 6 0.003; t 5 5.95; P ,0.001). There were no significant differences between the recovered ICG concentrations and the expected values at any of the four dye concentrations. Zweens and Frankena (4 ) demonstrated tha...

متن کامل

Human plasma derived drugs separation by fractionation of plasma with polyethylene glycol

Background: There are varieties of purification techniques for separation of human plasma proteins such as salting out, ion exchange chromatography, and ethanol fractionation. There are limitations for each method, for example in salting out method, the salt has to be removed in an additional step. Ion exchange chromatography is difficult for scaling up, and plasma fractionation is a time consu...

متن کامل

Modification of polyethylene glycol estimation suitable for use with small mammals.

Concentration of polyethylene glycol (PEG) has been measured satisfactorily using only 0.25 ml of intestinal aspirate (containing approximately 2.5 mg/l PEG). Hyden's turbidimetric assay was modified by reading turbidity at 420 mmu. The addition of extra protein was found to facilitate filtration after protein precipitation.

متن کامل

Impact of the time window on plasma volume measurement with indocyanine green.

Recent reports have questioned the accuracy of the indocyanine green dilution technique for measuring plasma volume. Our objective was to evaluate the impact of different time windows for monoexponential extrapolation. We retrospectively analysed 31 indocyanine green decay curves to investigate the problem in principle (group 1) and prospectively performed another 21 plasma volume measurements ...

متن کامل

One-pot and efficient synthesis of triazolo[1,2-a]indazole-triones catalyzed by poly(ethylene glycol) based magnetic dicationic ionic liquid

An atom-efficient, eco-friendly, solvent-free, high yielding, multicomponent green strategy to synthesize triazolo[1,2-a]indazole-triones derivatives by the one-pot condensation of aldehyde, dimedone, and phenyl urazole is presented. A series of different substituted aromatic aldehydes including either electron-withdrawing or electron-donating groups used in this reaction participated well and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 10  شماره 

صفحات  -

تاریخ انتشار 2001