Comparing DTL microfiber and Neuroline skin electrode in the Mini Ganzfeld ERG

نویسندگان

  • Anastasia Lapkovska
  • Anja M. Palmowski-Wolfe
  • Margarita G. Todorova
چکیده

BACKGROUND In infant ERG recordings skin electrodes frequently result in a better compliance. In order to assess the quality of such recordings, we compared the recording characteristics of DTL microfiber and Neuroline surface electrodes using a modified ISCEV protocol in the Mini Ganzfeld ERG. METHODS A prospective cohort study on healthy adult subjects was conducted at the Department of Ophthalmology, University of Basel, Switzerland. Thirty healthy volunteers were tested. The microfiber electrode (DTL Plus Electrode) was placed across the cornea, above the lower eyelid. The Neuroline skin electrode was placed on the surface of the lower lid on the opposite eye. The eye on which each electrode type was placed was randomised. Amplitudes of the rod, standard combined, standard flash cone, light-adapted 3.0 Hz flicker and red cone responses were analysed, as well as their respective implicit times. RESULTS Both electrode recordings showed the same waveform characteristics. Responses with the Neuroline electrode were significantly weaker than those from the DTL electrode. Amplitudes of the rod, standard combined, standard flash cone, light-adapted 3.0 Hz flicker and red cone responses were up to four times larger when recorded with the DTL electrode (p < 0.005, ANOVA). Implicit times of the red cone ERGs were slightly faster for the Neuroline skin electrode recordings (p ≤ 0.039). CONCLUSIONS Comparison of full-field ERG recordings with microfiber DTL and Neuroline skin electrodes showed that DTL electrodes produce larger ERGs. Hence, we provide evidence that both electrode types allow successful full-field ERG recording, although separate normative data for both electrodes are necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of different recording parameters to establish a standard for flash electroretinography in rodents

Different electrodes and stimulus protocols commonly used for electroretinography in rodent eyes were compared for convenience of use, degree of damage to corneal epithelium, and for magnitude of amplitude, reproducibility, left versus right eye accuracy, and reliability of recorded parameters of the flash electroretinogram (ERG). Adult C57BL/6 pigmented mice and albino Wistar rats were used to...

متن کامل

Comparison between Dawson, Trick, and Litzkow electrode and contact lens electrodes used in clinical electroretinography.

PURPOSE To determine the reliability of the Dawson, Trick, and Litzkow (DTL) electrode in electroretinographic recordings (ERG) in subjects of all ages, we evaluated ERG responses obtained with the contact lens (CL) and DTL electrodes and estimated a DTL/CL ratio for each sample. METHODS Seventy-nine volunteers aged 2-84 years (79 normal eyes) were recruited for the study. Electroretinographi...

متن کامل

Full-field electroretinogram recorded with skin electrodes in normal adults.

Purpose: Alternative recording methods have been tested to allow the electroretinogram (ERG) recording in uncooperative patients and/or patients with palpebral alterations, including recordings with skin electrodes. The purpose of this study was to compare ERG recorded with skin electrodes and well-established microfiber electrodes and to determine normative values of ERG parameters for recordi...

متن کامل

Reproducibility of ERG responses obtained with the DTL electrode

Previous investigators have suggested that the DTL fibre electrode might not be suitable for the recording of replicable electroretinograms. We present experimental evidence that when used adequately, this electrode does permit the recording of highly reproducible retinal potentials.

متن کامل

The influence of retinal preprocessing in visual cortex oscillations in humans

The present report addresses the reliability of non-invasive retinal recordings in humans using two different recording techniques for retinal activity – skin and DTL electrodes. As skin refers to a common disc electrode on the skin surface and DTL to a contact-electrode with a silver-silver chloride coated fibre. Although the literature suggests that the DTL electrode provides stronger signal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016