Transcranial measurement of cerebral microembolic signals during pulmonary vein isolation: a comparison of two ablation techniques.

نویسندگان

  • Edina Nagy-Baló
  • Diana Tint
  • Marcell Clemens
  • Ildikó Beke
  • Katalin Réka Kovács
  • László Csiba
  • István Édes
  • Zoltán Csanádi
چکیده

BACKGROUND Pulmonary vein isolation has increasingly been used to cure atrial fibrillation, but concerns have recently been raised that subclinical brain damage may occur because of microembolization during these procedures. We compared the occurrence of bubble formation seen on intracardiac echocardiography and the microembolic signals (MESs) detected by transcranial Doppler on the use of different ablation techniques and anticoagulation strategies. METHODS AND RESULTS This prospective study included 35 procedures in 34 consecutive patients (age, 52; SD, 12.8 years; female:male 9:25). Pulmonary vein isolation was performed with a cryoballoon and the conventional anticoagulation protocol (activated clotting time >250 s) in 10 procedures (group 1), with a multipolar duty-cycled radiofrequency pulmonary group 2), and with regime a pulmonary vein ablation catheter with an aggressive anticoagulation (activated clotting time >320 s) in 13 procedures (group 3). The mean total numbers of MESs detected during the procedures were 833.7 (SD, 727.4) in group 1, 3142.6 (SD, 1736.4) in group 2, and 2204.6 (SD, 1078.1) in group 3 (P=0.0005). MESs were detected mostly during energy delivery in the pulmonary vein ablation catheter groups, whereas a relatively even distribution of emboli formation was seen during cryoballoon ablations. A significant correlation was found in all groups between the degree of bubble formation on intracardiac echocardiography and the number of MESs (P=0.0000). CONCLUSIONS Duty-cycled radiofrequency ablation is associated with significantly more MESs, even when more aggressive anticoagulation is applied. With both techniques most of these microemboli are gaseous in nature.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcranial Measurement of Cerebral Microembolic Signals During Pulmonary Vein

Edina Nagy-Baló, Diana Tint, Marcell Clemens, Ildikó Beke, Katalin Réka Kovács, László Isolation: A Comparison of Two Ablation Techniques Transcranial Measurement of Cerebral Microembolic Signals During Pulmonary Vein Print ISSN: 1941-3149. Online ISSN: 1941-3084 Copyright © 2013 American Heart Association, Inc. All rights reserved. Avenue, Dallas, TX 75231 is published by the American Heart As...

متن کامل

Online Measurement of Microembolic Signal Burden by Transcranial Doppler during Catheter Ablation for Atrial Fibrillation—Results of a Multicenter Trial

INTRODUCTION Left atrial pulmonary vein isolation (PVI) is an accepted treatment option for patients with symptomatic atrial fibrillation (AF). This procedure can be complicated by stroke or silent cerebral embolism. Online measurement of microembolic signals (MESs) by transcranial Doppler (TCD) may be useful for characterizing thromboembolic burden during PVI. In this prospective multicenter t...

متن کامل

Influence of Clinical Parameters and Anticoagulation on Intraprocedural Cerebral Microembolic Signals during Pulmonary Vein Isolation

OBJECTIVE We had the objective to determine the impact of clinical parameters and anticoagulation status on cerebral microembolic signals (MES) during pulmonary vein isolation (PVI) for atrial fibrillation (AF). BACKGROUND Thromboembolism and stroke are the most feared complications of PVI. MES can help to evaluate embolic burden. It is unknown whether clinical parameters have an impact on em...

متن کامل

Cerebral micro-embolization during pulmonary vein isolation: Relation to post-ablation silent cerebral ischemia.

BACKGROUND High incidences of silent cerebral ischemia (SCI) have been revealed by diffusion-weighted magnetic resonance imaging (DW MRI) after pulmonary vein isolation (PVI) for atrial fibrillation. A high number of mostly gaseous micro-embolic signals (MESs) was detected by transcranial Doppler (TCD) during PVI. In this investigation the possible relationship between MESs detected intraoperat...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 6 3  شماره 

صفحات  -

تاریخ انتشار 2013