Use of Hybrid Shunt Active Power Filter for Power Quality Improvement
نویسندگان
چکیده
Supply of uninterrupted sinusoidal voltage of constant magnitude is the most important aim of the electrical distribution system, but this task is very tough and is becoming more difficult due to the increasing size and number of nonlinear and poor power factor loads. Some of the most important causes of poor power quality is harmonics and high neutral current. Harmonics and neutral current deteriorate power quality as well as affect the system at large and makes significant impact. In this paper a control scheme based on PI controller has been proposed for generation of reference current to mitigate the harmonics and neutral current for two different topologies. The proposed methodology not only reduces the complexity but also offers simplicity to implement and increases reliability of the system. Analysis and simulation of three phase four wire shunt active power filter under balanced and unbalanced load condition have been done using MATLAB/ SIMULINK and detailed simulation level results have been presented to validate the proposed methodology.
منابع مشابه
A Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks
The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...
متن کاملA Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach
This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...
متن کاملPower Quality Improvement of Pv Power Generation Systems Using Hybrid Filter
A hybrid filter constructed of a shunt active filter and distributed passive filters used for power quality improvement in PV power generating systems is presented. The distribution system consists of a photovoltaic power generation system and several dynamic nonlinear loads. The power quality problems of dispersed generation low voltage systems are introduced and the necessity of using hybrid ...
متن کاملCompensation Strategies for Shunt Active Power Filter in Single- and Three-Phase Systems: Different Formulation, Comparison and Evaluation
متن کامل
Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملHarmonic Reduction in Hybrid Filters for Power Quality Improvement in Distribution Systems
A flexible and versatile solution to voltage quality problems is offered by active power filters. Currently they are based on PWM converters and used to connect to low and medium voltage distribution system in shunt or in series. Active power filters can perform one or more of the functions required to compensate power systems in improving power quality. Hybrid Filter, which is a combination of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014