Diagnosis of dynamitron accelerator faults through the observation of narrow nuclear resonances

نویسنده

  • L. G. Earwaker
چکیده

2014 Narrow nuclear resonances, initially used to calibrate the energy of the Birmingham Radiation Centre 3MV Dynamitron, have proved useful in discovering and identifying accelerator fault conditions. Short-term energy stability (over e few minutes) of a few tens of eV is common. However, variations of many kV occur for several days before the failure of a thermionic rectifier. The beam energy ripple, as reflected in the full width at half maximum of narrow (p,03B3) resonances, has also been analysed to indicate the frequency causing the bulk of the ripple, thus often leading to the identification and correction of faults. Typical faults usually produce increased ripple at either the 50 Hz or 128 kHz oscillator frequency. REVUE DE PHYSIQUE APPLIQUÉE TOME 12, OCTOBRE 1977, PAGE

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Single and Dual Incipient Process Faults Using an Improved Artificial Neural Network

Changes in the physicochemical conditions of process unit, even under control, may lead to what are generically referred to as faults. The cognition of causes is very important, because the system can be diagnosed and fault tolerated. In this article, we discuss and propose an artificial neural network that can detect the incipient and gradual faults either individually or mutually. The mai...

متن کامل

Cytochrome c: observation of numerous single-carbon sites of the reduced and oxidized species by means of natural-abundance 13C nuclear magnetic resonance spectroscopy.

Proton-decoupled, natural-abundance (13)C nuclear magnetic resonance spectra (obtained at 15.18 MHz by the Fourier transform method) of aqueous ferrocytochrome c, ferricytochrome c, and mixtures of both species were recorded. The 18 nonprotonated aromatic carbons of amino-acid residues and the 16 nonprotonated aromatic carbons of the heme yielded 22 narrow single-carbon resonances and 6 narrow ...

متن کامل

Test of the universality of the three-body Efimov parameter at narrow Feshbach resonances.

We measure the critical scattering length for the appearance of the first three-body bound state, or Efimov three-body parameter, at seven different Feshbach resonances in ultracold ^{39}K atoms. We study both intermediate and narrow resonances, where the three-body spectrum is expected to be determined by the nonuniversal coupling of two scattering channels. Instead, our observed ratio of the ...

متن کامل

A Biomechanical Approach for the Study of Deformation of Red Cells in Narrow Capillaries

This model focuses on the behavior of capillary-tissue fluid exchange system when the diameter of the capillary is less than that of red cell. In vivo and in vitro observations indicate that the width of the gap between the red cell and the vessel wall is generally small compared to the radius of the capillary for a single file flow of red cell in narrow vessel, particularly if the vessel diame...

متن کامل

Fault diagnosis in a distillation column using a support vector machine based classifier

Fault diagnosis has always been an essential aspect of control system design. This is necessary due to the growing demand for increased performance and safety of industrial systems is discussed. Support vector machine classifier is a new technique based on statistical learning theory and is designed to reduce structural bias. Support vector machine classification in many applications in v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016