Implementation of biological variation-based analytical performance specifications in the laboratory: Stringent evaluation of Improvacutor blood collection tubes
نویسندگان
چکیده
Recently, because the quality of laboratory analyses has increased along with the need for quality improvement, several external quality control bodies have adapted performance specifications using the Desirable Biological Variation Database, termed "Ricos goals"; these criteria are more stringent than those presented in CLIA 88. In this study, we aimed to validate newly introduced serum separator tubes, Improvacutor, for routine clinical chemistry testing in accordance with Ricos goals and CLIA 88. Blood samples were collected from 100 volunteers into three types of serum vacuum tubes: Greiner Vacuette, Becton Dickinson (BD) Vacutainer, and Improve Improvacutor. The samples were subjected to 16 routine chemistry tests using a TBA-200fr NEO chemistry autoanalyzer. In the comparison analysis, all 16 test results were acceptable according to CLIA 88. However, in the comparison of Improve and BD tubes, creatinine showed 4.31% (+0.08 μmol/L) bias. This slightly exceeded the Desirable Specification for Inaccuracy Ricos limit of ±3.96%, but still satisfied the CLIS88 limit of ±26.52 μmol/L. The remaining 15 analytes performed acceptably according to the Desirable Specifications of Ricos. The correlation coefficient of 12 analytes was greater than 0.95 in Passing-Bablok regression analysis among the three tubes, but was lower for four analytes: calcium, sodium, potassium, and chloride. In the stability assay, only potassium tested in the Greiner tube revealed a larger positive bias (2.18%) than the Ricos Desirable Specification for Inaccuracy based on biologic variation (1.8%). The BD tube also showed a positive bias of 1.74%, whereas the new Improve tube showed the smallest positive bias of 1.17% in potassium level after 72 h storage. Thus, the results of this study demonstrate that recently introduced analytical performance specifications based on components of biological variation (Rico's goal) could be extended to criterion for performance evaluation and applied.
منابع مشابه
Performance Comparison of Two Different Branded Blood Collection Tubes Used in Biochemistry Laboratory
Background and Aims: Blood collection tubes (BCT) with gel separators are diagnostic devices that can affect all laboratory processes. In this study, the aim was to compare the performance of a new brand of BCT with the sample tubes that are well-known and widely used in the market. Materials and Methods: Blood samples were taken from 50 healthy volunteers to two brands of BCTs (KWS and BD Vac...
متن کاملQuality specifications for the determination of copper, zinc, and selenium in human serum or plasma: evaluation of an approach based on biological and analytical variation.
BACKGROUND Trace element external quality assessment schemes monitor laboratory performance and provide a stimulus for improvement in accuracy. However, monitoring of participant performance varies according to the scheme and can lead to conflicting conclusions. METHODS Quality specifications based on biological intra- and interindividual variability were calculated and compared to those curr...
متن کاملCan current analytical quality performance of UK clinical laboratories support evidence-based guidelines for diabetes and ischaemic heart disease?--A pilot study and a proposal.
BACKGROUND The implementation of national and international guidelines is beginning to standardise clinical practice. However, since many guidelines have decision limits based on laboratory tests, there is an urgent need to ensure that different laboratories obtain the same analytical result on any sample. A scientifically-based quality control process will be a pre-requisite to provide this le...
متن کاملGeir Thue and Sverre Sandberg * Analytical performance specifications based on how clinicians use laboratory tests . Experiences from a post - analytical external quality assessment programme
Analytical performance specifications can be based on three different models: the effect of analytical performance on clinical outcome, based on components of biological variation of the measurand or based on stateof-the-art. Models 1 and 3 may to some degree be combined by using case histories presented to a large number of clinicians. The Norwegian Quality Improvement of Primary Care Laborato...
متن کاملThe 1999 Stockholm Consensus Conference on quality specifications in laboratory medicine.
The setting of analytical quality specifications in laboratory medicine has been a topic of discussion and debate for over 50 years: 15 years ago, as the subject matured and a profusion of recommendations appeared, many of them from expert groups, it was realised by a number of leading professionals that there was a need for a global consensus on the setting of such specifications. The Stockhol...