A Trio of Modulators for the Fermilab Tevatron Electron Lens Project
نویسندگان
چکیده
Three high voltage modulators used during testing and operation of the Tevatron Electron Lens (TEL) at Fermilab will be described. Short high voltage (0 to ~20kV) pulses from these modulators vary the anode-cathode voltage of the TEL electron gun to control the magnitude of the electron beam current. The trio of modulators include a low repetition rate MOSFET-based pulser, a fast ionization device, and a high average power tetrode modulator The characteristics of each device will be discussed and typical outputs from each type of modulator will be shown.
منابع مشابه
Experimental demonstration of colliding-beam-lifetime improvement by electron lenses.
We report the successful application of space-charge forces of a low-energy electron beam for improvement of particle lifetime determined by beam-beam interaction at a high-energy collider. In our experiments, an electron lens, a novel instrument developed for the beam-beam compensation, was set on a 980-GeV proton bunch at the Fermilab Tevatron proton-antiproton collider. The proton-bunch loss...
متن کاملCollimation with Hollow Electron Beams: A Proposed Design for the LHC Upgrade
Collimation with hollow electron beams is a technique for halo removal in high-power hadron beams. The concept was tested experimentally at the Fermilab Tevatron collider using a hollow electron gun installed in one of the Tevatron electron lenses. Within the US LHC Accelerator Research Program and the European HiLumi LHC Design Study, we are investigating the applicability of this technique to...
متن کاملEiichiro KomatsuDiagnostics of the Fermilab Tevatron Using an AC Dipole
vii Chapter 1 The Fermilab Tevatron 1 1.1 Tevatron as a Collider Synchrotron . . . . . . . . . . . . . . . 3 1.2 Luminosity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.3 Synchrotron Diagnostics . . . . . . . . . . . . . . . . . . . . . 9 1.4 Outline of This Dissertation . . . . . . . . . . . . . . . . . . . 10 Chapter 2 Particle Motion in an Ideal Synchrotron 12 2.1 Quadrupole M...
متن کاملFermilab Electron Cooling Project: Engineering Aspects of Cooling Section
The Fermilab Electron Cooling project involves interacting a 4.3 MeV, 0.5 A DC electron beam with 8.9 GeV/c antiprotons in the FNAL Recycler Ring. This interaction occurs through a 20-meter long cooling section consisting of 10 solenoid modules. This cooling process would lead to an increase in the Tevatron collider luminosity needed to support RunIIb parameters. There are several important eng...
متن کاملStatus of the Fermilab Electron Cooling Project
The first stage of the Fermilab Electron Cooling R&D program is now complete: technology necessary to generate hundreds of milliamps of electron beam current at MeV energies has been demonstrated. Conceptual design studies show that with an electron beam current of 200 mA and with a cooling section of 20 m electron cooling in the Fermilab Recycler ring can provide antiproton stacking rates suit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -