Systematic Review of the Diagnostic Accuracy of Haptoglobin, Serum Amyloid A, and Fibrinogen versus Clinical Reference Standards for the Diagnosis of Bovine Respiratory Disease

نویسندگان

  • A. Abdallah
  • J. Hewson
  • D. Francoz
  • H. Selim
  • S. Buczinski
چکیده

BACKGROUND Bovine respiratory disease (BRD) is a worldwide animal health concern especially in feedlot, dairy, and veal calves. One of the greatest challenges is the absence of a gold standard for achieving an accurate antemortem diagnosis. Various blood markers, including the acute-phase proteins (AAP), have been proposed as potential valuable tools for BRD diagnosis. OBJECTIVES To perform a systematic review of the literature to assess the accuracy of selected APP (haptoglobin [Hp], serum amyloid A [SAA], and fibrinogen [Fb]) as diagnostic tools for cattle with naturally occurring BRD when compared with clinical reference standards of diagnosis. METHODS This review was performed with eligible studies selected from CAB Abstract and MEDLINE from 1946 to 2015, as well as the "gray literature." Methodological quality of included studies was assessed using the QUADAS-2 tool developed for diagnostic accuracy studies. The accuracy parameters sensitivity (Se) and specificity (Sp) were obtained from the articles or through contact with the authors when not directly reported. RESULTS A total of 314 studies were identified, from them, 23 met inclusion criteria as diagnostic studies for naturally occurring BRD. Quality of studies showed high risk of bias for case selection (70% of articles) and unclear risk of bias for index test (65%), reference standard (74%), and flow and timing (61%). There were high concerns regarding applicability for case selection (61% of studies) and reference standards used for defining BRD (48%). The concerns regarding index test application were low (83% of the studies). Only 4-8 studies could be included in the meta-analysis for each APP. No pooled estimates or pooled accuracy measurements were performed due to the low number of studies and multiple differences between studies, including reference standard definitions. CONCLUSIONS AND CLINICAL IMPORTANCE On the basis of these findings, it is not possible to make conclusions regarding the accuracy of APP for BRD diagnosis. The reporting of accuracy of APP for BRD detection is inconsistent among studies. Recommendations to improve capability for future meta-analyses in this area include reporting studies on diagnostic tests following the Standard for the Reporting of Diagnostic Accuracy Studies (STARD), as well as trying to standardize BRD definition across future studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serum Amyloid A (SAA) as Early Diagnosis of COVID-19 Disease: A Systematic Review and Meta-Analysis

Background and Aim: In December 2019, human-to-human transmission of respiratory illness (pneumonia) with fever and sputum was discovered in the respiratory tract, called COVID-19. Serum amyloid A (SAA) is an acute-phase plasma protein that is considered to be diagnostically superior to CRP in pathological conditions such as viral diseases. Therefore, the study question in this review is whethe...

متن کامل

Serum concentrations of haptoglobin and serum amyloid A in water buffaloes (Bubalus bubalis) with abomasal ulcer

To evaluate the serum concentrations of haptoglobin (Hp) and serum amyloid A (SAA) in water buffaloes with abomasal ulcers, the abomasums of 100 randomly selected water buffaloes were examined after slaughter. Type I abomasal ulcers were found in 56 out of 100 buffaloes. Serum concentrations of Hp and SAA were measured. There was no significant difference between affected and non-affected buffa...

متن کامل

Changes of acute-phase proteins during different phases of the estrous cycle in Ovsynch-synchronized Holstein cows

Background: Acute-phase proteins (APPs) may be increased due to different stresses during estrus phase in farm animals. Aims: Determining changes of APPs at different phases of non-synchronized estrous cycle group (NSEG), and Ovsynch-synchronized estrous cycle group (SEG) in Holstein cows. Methods: Twelve non-pregnant clinically and paraclinicaly healthy Holstein cows with a body condition scor...

متن کامل

The relationships among acute phase response proteins, cytokines, and enzymes during ovine experimental endotoxemia

BACKGROUND: The acute phase response is beneficial to theanimal in restoring homeostasis, and measuring the circulatingacute phase proteins, cytokines, and enzymes can be used toevaluate the innate immune system's responses to invader agentssuch as bacterial lipopolysaccharide. Measurement of theseparameters has shown to be useful as diagnostic and prognosticmarkers in animal endotoxemia. OBJEC...

متن کامل

Determination of serum haptoglobin reference value in clinically healthy Iranian fat-tailed sheep

Blood samples were collected from the jugular vein of 101 clinically healthy Iranian fat-tailed sheep according to their age (5 years) and sex. Serum haptoglobin (Hp) was measured based upon the preservation of the peroxidase activity of haemoglobin, which is directly proportional to the amount of Hp. The reference value for serum Hp of apparently healthy Iranian fat-tailed sheep was 0.05-0.18 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2016