Data-driven classification of ventilated lung tissues using electrical impedance tomography.
نویسندگان
چکیده
Current methods for identifying ventilated lung regions utilizing electrical impedance tomography images rely on dividing the image into arbitrary regions of interest (ROI), manually delineating ROI, or forming ROI with pixels whose signal properties surpass an arbitrary threshold. In this paper, we propose a novel application of a data-driven classification method to identify ventilated lung ROI based on forming k clusters from pixels with correlated signals. A standard first-order model for lung mechanics is then applied to determine which ROI correspond to ventilated lung tissue. We applied the method in an experimental study of 16 mechanically ventilated swine in the supine position, which underwent changes in positive end-expiratory pressure (PEEP) and fraction of inspired oxygen (F(I)O(2)). In each stage of the experimental protocol, the method performed best with k = 4 and consistently identified 3 lung tissue ROI and 1 boundary tissue ROI in 15 of the 16 subjects. When testing for changes from baseline in lung position, tidal volume, and respiratory system compliance, we found that PEEP displaced the ventilated lung region dorsally by 2 cm, decreased tidal volume by 1.3%, and increased the respiratory system compliance time constant by 0.3 s. F(I)O(2) decreased tidal volume by 0.7%. All effects were tested at p < 0.05 with n = 16. These findings suggest that the proposed ROI detection method is robust and sensitive to ventilation dynamics in the experimental setting.
منابع مشابه
Classification of normal and cancerous lung tissues by electrical impendence tomography.
Biological tissue impedance spectroscopy can provide rich physiological and pathological information by measuring the variation of the complex impedance of biological tissues under various frequencies of driven current. Electrical Impedance Tomography (EIT) technique can measure the impedance spectroscopy of biological tissue in medical field. Before application, a key problem must be solved on...
متن کاملLiterature List Electrical Impedance Tomography
Breathing moves volumes of electrically insulating air into and out of the lungs, producing conductivity changes which can be seen by electrical impedance tomography. It has thus been apparent, since the early days of EIT research, that imaging of ventilation could become a key clinical application of EIT. In this paper, we review the current state and future prospects for lung EIT, by a synthe...
متن کاملMechanical ventilation guided by electrical impedance tomography in experimental acute lung injury.
OBJECTIVE To utilize real-time electrical impedance tomography to guide lung protective ventilation in an animal model of acute respiratory distress syndrome. DESIGN Prospective animal study. SETTING Animal research center. SUBJECTS Twelve Yorkshire swine (15 kg). INTERVENTIONS Lung injury was induced with saline lavage and augmented using large tidal volumes. The control group (n = 6) ...
متن کاملElectrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial
INTRODUCTION Computed tomography of the lung has shown that ventilation shifts from dependent to nondependent lung regions. In this study, we investigated whether, at the bedside, electrical impedance tomography (EIT) at the cranial and caudal thoracic levels can be used to visualize changes in ventilation distribution during a decremental positive end-expiratory pressure (PEEP) trial and the r...
متن کاملElectrical impedance tomography system based on active electrodes.
Electrical impedance tomography (EIT) can image the distribution of ventilated lung tissue, and is thus a promising technology to help monitor patient breathing to help selection of mechanical ventilation parameters. Two key difficulties in EIT instrumentation make such monitoring difficult: (1) EIT data quality depends on good electrode contact and is sensitive to changes in contact quality, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological measurement
دوره 32 7 شماره
صفحات -