Influence of photon scattering and attenuation on ROI analysis in brain perfusion single-photon emission tomographic imaging of normal subjects.

نویسندگان

  • Jingming Bai
  • Jun Hashimoto
  • Koichi Ogawa
  • Atsushi Kubo
  • Atsushi Fukunaga
  • Satoshi Onozuka
  • Koichi Uchida
چکیده

OBJECTIVE The aim of this study was to evaluate the effect of scatter and attenuation correction in region of interest (ROI) analysis in brain perfusion single-photon emission tomography (SPECT) and to assess the influence of selecting the reference area on semi-quantification. METHODS Ten normal subjects were enrolled and injected with 123I-iodoamphetamine to undergo simultaneous emission and transmission scanning for scatter and attenuation correction. We reconstructed three SPECT images from common projection data of each subject: with scatter correction and non-uniform attenuation correction, with scatter correction and uniform attenuation correction, and with uniform attenuation correction applied to data without scatter correction. A program for automated ROI drawing was used to set ROIs on various regions in brain images. Regional count ratios were compared in images with different correction procedures by using three different reference areas. RESULTS The effect of the combination of scatter and attenuation correction was marked in the precentral, temporal, posterior, hippocampus and especially in the cerebellum. In contrast, it was not appreciable in the central and parietal areas. When using the cerebellar ROI as the reference, the count ratio varied widely depending on the correction procedures. On the other hand, the whole brain reference offered the least variation in the count ratio. CONCLUSIONS The influence of photon scattering and attenuation was dependent on regions. Since the count in the cerebellar ROI is greatly affected by photon scattering and attenuation, nonuniform attenuation correction combined with scatter correction deserves consideration when using the cerebellar ROI as the reference.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]

Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...

متن کامل

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

Assessment of the impact of applying attenuation correction on the accuracy of activity recovery in Tc99m-ECD brain SPECT of healthy subject using Statistical Parametric Mapping (SPM)

Introduction: Photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed Single Photon Emission Computed Tomography (SPECT) images. The aim of present study was to investigate the effect of attenuation correction on the detection of activation foci following statistical analysis w...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Brain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review

Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 19 7  شماره 

صفحات  -

تاریخ انتشار 2005