Echocardiographic integrated backscatter for detecting progression and regression of aortic valve calcifications in rats
نویسندگان
چکیده
BACKGROUND Calcification is an independent predictor of mortality in calcific aortic valve disease (CAVD). The aim of this study was to evaluate the use of non-invasive, non-ionizing echocardiographic calibrated integrated backscatter (cIB) for monitoring progression and subsequent regression of aortic valvular calcifications in a rat model of reversible renal failure with CAVD, compared to histology. METHODS 28 male Wistar rats were prospectively followed during 21 weeks. Group 1 (N=14) was fed with a 0.5% adenine diet for 9 weeks to induce renal failure and CAVD. Group 2 (N=14) received a standard diet. At week 9, six animals of each group were killed. The remaining animals of group 1 (N=8) and group 2 (N=8) were kept on a standard diet for an additional 12 weeks. cIB of the aortic valve was calculated at baseline, 9 and 21 weeks, followed by measurement of the calcified area (Ca Area) on histology. RESULTS At week 9, cIB values and Ca Area of the aortic valve were significantly increased in the adenine-fed rats compared to baseline and controls. After 12 weeks of adenine diet cessation, cIB values and Ca Area of group 1 decreased compared to week 9, while there was no longer a significant difference compared to age-matched controls of group 2. CONCLUSIONS cIB is a non-invasive tool allowing quantitative monitoring of CAVD progression and regression in a rat model of reversible renal failure, as validated by comparison with histology. This technique might become useful for assessing CAVD during targeted therapy.
منابع مشابه
Echocardiographic integrated backscatter for the differentiation between aortic valve calcification and valvular myxoid degeneration in rats.
AIMS Calcification is an independent predictor of mortality in aortic valve (AV) stenosis. Echocardiographic calibrated integrated backscatter (cIB) is a promising parameter for quantifying AV calcification. However, the ability of cIB to differentiate between calcification and valvular thickening has been questioned. Therefore, we aimed to use cIB to study AV calcification compared with non-ca...
متن کاملDoppler echocardiographic findings in tissue engineered aortic valve in a sheep model
Background: Heart valve diseases are considered a common disease in human and animals, and valve replacement is an option for treatment of valvular diseases. Objectives: In this study efficacy of a tissue engineered valve in thoracic aorta was evaluated with transthoracic echocardiography. Methods: This study was undertaken on 6 male sheep. Echocardiography was performed on all sheep 24 hours b...
متن کاملA rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure
Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...
متن کاملگزارش 3 بیمار مبتلا به تونل آئورت به بطن چپ
Aorto-left ventricular tunnel (ALVT) is a rare congenital anomaly in which an abnormal communication connects the ascending aorta with the left ventricle, that results volume overload on left ventricle. It is clinically undistinguishable from aortic insufficiency. Its prompt and precise diagnosis is crucial since early surgical treatment is definitely indicated. In this report clinical,...
متن کاملSensitivity and specificity of two-dimensional echocardiography in the detection of valvular calcification.
To test the ultrasonic method for detecting valvular calcifications, two-dimensional echocardiograms and 35-mm cinefluorograms recorded in 113 elderly men were compared. Four views of the heart were filmed with image intensification. Valvular opacifications 1.5 mm or more in diameter were considered to be calcium and served as the standards. From parasternal views the brightness of valvular ech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2013