A Two Element Phased Array Coil Enabling Widespread Application of High Resolution MR Coronary Angiography
نویسندگان
چکیده
Parallel imaging using sophisticated receiver coils has improved the clinical feasibility of magnetic resonance coronary angiography (MRCA). These techniques, however, are not readily available outside advanced imaging centers. Our custom-made 2-element phased array coil is readily and inexpensively assembled to address this limitation and enable the widespread application of MRCA. The 2-element phased array coil, comprised of two 4-inch, overlapping circular coils, is specifically designed for MRCA. We compare our prototype coil to two commercially available coils commonly used for MRCA. MRCA has been performed in 14 normal volunteers. Anatomic coverage, image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) are calculated for each coil. The prototype coil has imaged 92.6% (125/135) of the segments compared to 83.7% (113/135) and 76.3% (103/135) (p = 0.002) using the surface coil and cardiac phased array coil, respectively. Excellent or good (grade 1-2) image quality has been attained in 85.9% (116/135) of all the coronary segments using the prototype coil compared to 77.0% (104/135) and 71 % (96/135) using the surface and cardiac phased array coils, respectively (p = 0.025). Overall, higher SNR and CNR have been achieved by the prototype coil compared to the surface and the cardiac phased array coils (SNR: 13.5 ± 5.3 vs 12.2 ± 3.7 vs 9.0 ± 3.1 and CNR: 7.5 ± 5.5 vs 6.2 ± 3.3 vs 3.7 ± 2.7, respectively). Compared to two commercially available coils, the 2-element phased array coil is associated with overall improved SNR and CNR and provides higher image quality with wider anatomic coverage.
منابع مشابه
Effectiveness of 32-element Surface Coil Array for Accelerated Volume-Targeted Breath-Hold Coronary MRA
Purpose : To compare 12 and 32-element surface coil arrays for highly accelerated coronary magnetic resonance angiography (MRA) using parallel imaging. Materials and Methods : Steady state free precession coronary MRA was performed in 5 healthy volunteers at 1.5 T whole body MR scanner using both 12 and 32-element surface coil arrays. Left anterior descending and right coronary artery data sets...
متن کاملPhased-Array Coils for MR Microscopy of the Skin in vivo
100 WORD ABSTRACT An RF receive-only phased-array coil for high-resolution in vivo imaging of human skin was developed. Simulations of signal-to-noise ratio (SNR) for various coil geometries—single loops and 2 and 3-element phased-arrays—were performed with respect to the special noise characteristics of small coils. The 2element phased-array coil was implemented. SNR measurements in a phantom ...
متن کاملBody-coil nonenhanced MR angiography using highly undersampled radial QISS
Background Current approaches for magnetic resonance angiography (MRA) require the use of parallel imaging in order to keep scan times short and obtain adequate slice coverage and spatial resolution. However, parallel imaging necessitates the use of phased array coils, which increases setup time and restricts the vascular territory that can be imaged. We hypothesized that using Quiescent-Inflow...
متن کاملDesign and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system.
PURPOSE Magnetic resonance imaging (MRI) of rodents can be expected to be a growing application, particularly when translatory imaging research "from mouse to man" is envisioned. 7 T high-field human whole-body MR systems provide a powerful platform for high-resolution small animal imaging. For achieving adequate spatial resolution, dedicated radiofrequency coils have to be designed to provide ...
متن کامل3.0T contrast-enhanced, submilimeter MRA of the supraaortic arteries: does the signal gain at high field strength allow to replace the phased array coil by the quadrature body coil?
Purpose of the study was to evaluate contrast-enhanced MR angiography (CE MRA) of the supraaortic arteries at 3.0T using the quadrature body coil as transmitter and receiver. CE MRA was performed with randomly segmented central k-space ordering (CENTRA) in 43 patients and 5 volunteers using a large FOV (350 mm) and a high image matrix of 432 x 432 (nonzerofilled voxel: 0.66 mm3).Our experience ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009