Transmission Mains Earthing Design: Under Ground to Over Head Pole Transition
نویسندگان
چکیده
The demand on High voltage (HV) infrastructures is growing due to the corresponding growth in industries and population. New or upgraded HV infrastructure has safety implications since Transmission mains usually occupy the same easement in the vicinity of neighbouring residents. Transmission mains consist of underground (UG) and overhead (OH) sections and the transition between the UG and OH section is known as the UGOH pole. The existence of two transmission mains in the same easement can dictate to resort to more complicated earthing design in order to mitigate the effect of AC interference, and in some cases it can also necessitates completing a Split Study of the system. This paper provides an overview of the AC interference, Split Study and the earthing of an underground feeder including the UGOH pole .In addition, this paper discusses the use of different link boxes on the UG feeder and presents a case study that represent a clear example of the Ac interference and Split factor. Finally, a few recommendations are provided to achieve a safety zone in the area beyond the boundary of the HV system. Keywords—UGOH, High Voltage, AC interference, Earthing Design.
منابع مشابه
Soil Resistivity Cut off Value and Concrete Pole Deployments in HV Transmission Mains
The prologue of new High Voltage (HV) transmission mains into the community necessitates earthing design to ensure safety compliance of the system. Concrete poles are widely used within HV transmission mains; many retired transmission mains with timber poles are being replaced with concrete ones, green transmission mains are deploying concrete poles. The earthing arrangement of the concrete pol...
متن کاملComparison of two simple high-frequency earthing electrodes - Generation, Transmission and Distribution, IEE Proceedings-
Lightning strikes on high-voltage transmission lines may create hazardous touch potentials on adjacent substation equipment and damage control equipment. When designing suitable substation earthing electrodes to overcome this problem and safely dissipate the transient fault currents to ground, it is essential to consider the behaviour of the current flow. The steadystate frequency equivalent to...
متن کاملHV Substation Earthing Design for Mines
-High Voltage (HV) substation forms important assets for the mining industries. The existences of these substations necessitate earthing design to ensure safety compliance to the mine regulations. The HV system within the mines is consisted of multiple substations which are connected throughout and underground cable. These substations provide the load with the required electrical power to perfo...
متن کاملSoftware Methods for Analysis of Transient Voltages Coupled to Shielded Cables in Hv Substations
Two main causes of such induced voltages in the shield are: time-varying magnetic flux and potential difference at the cable connections with the earthing system. It has been shown in that both components of the voltage along shield, due to ground potential difference and field coupling, are significant and moreover that they cancel each other. As a consequence, it is possible to optimize the d...
متن کاملPole-to-Ground Fault Analysis and Fast Protection Scheme for HVDC Based on Overhead Transmission Lines
Flexible direct current (DC) transmission network technology is an effective method for large capacity clean energy access to power grids, but the DC short-circuit fault detection for it is a difficult problem. In this paper, the pole-to-ground fault transient characteristics in a multi-terminal DC power grid, based on overhead transmission lines and DC circuit breakers, are analyzed firstly. T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013