Diagnosis of occupational asthma from time point differences in serial PEF measurements.
نویسندگان
چکیده
BACKGROUND The diagnosis of occupational asthma requires objective confirmation. Analysis of serial measurements of peak expiratory flow (PEF) is usually the most convenient first step in the diagnostic process. A new method of analysis originally developed to detect late asthmatic reactions following specific inhalation testing is described. This was applied to serial PEF measurements made over many days in the workplace to supplement existing methods of PEF analysis. METHODS 236 records from workers with independently diagnosed occupational asthma and 320 records from controls with asthma were available. The pooled standard deviation for rest day measurements was obtained from an analysis of variance by time. Work day PEF measurements were meaned into matching 2-hourly time segments. Time points with mean work day PEF statistically lower (at the Bonferroni adjusted 5% level) than the rest days were counted after adjusting for the number of contributing measurements. RESULTS A minimum of four time point comparisons were needed. Records with >or=2 time points significantly lower on work days had a sensitivity of 67% and a specificity of 99% for the diagnosis of occupational asthma against independent diagnoses. Reducing the requirements to >or=1 non-waking time point difference increased sensitivity to 77% and reduced specificity to 93%. The analysis was only applicable to 43% of available records, mainly due to differences in waking times on work and rest days. CONCLUSION Time point analysis complements other validated methods of PEF analysis for the diagnosis of occupational asthma. It requires shorter records than are required for the Oasys score and can identify smaller changes than other methods, but is dependent on low rest day PEF variance.
منابع مشابه
PEF analysis requiring shorter records for occupational asthma diagnosis.
BACKGROUND The Oasys programme plots serial peak expiratory flow (PEF) measurements and produces scores of the likelihood that the recordings demonstrate occupational asthma. We have previously shown that the area between the mean workday and rest day PEF curves [the area between the curves (ABC) score] has a sensitivity of 69% and specificity of 100% when plotted from waking time using a cut-o...
متن کاملAudit of quality of diagnostic procedures for occupational asthma.
BACKGROUND Previous studies have reported deficiencies in the quality of the diagnosis of occupational asthma. A low quality of diagnostic procedures means that the occupational cause of asthma is less likely to be revealed. AIMS To assess the current quality of the diagnosis of occupational asthma before referral to a specialist occupational medicine centre. METHODS The quality of diagnost...
متن کاملA Systematic Review of Serial Peak Expiratory Flow Measurements in the Diagnosis of Occupational Asthma
This paper systematically reviews literature on the application of serial peak expiratory flow (PEF) measurements in the diagnosis of occupational asthma and calculates summary estimates of the sensitivity, specificity, and feasibility of serial PEFs.
متن کاملSerial PEF measurement is superior to cross-shift change in diagnosing occupational asthma.
Cross-shift measurements of peak expiratory flow (PEF) are commonly employed in the diagnosis of occupational asthma, although evidence for this approach is lacking. The current paper presents an evaluation of the technique. Mean changes in PEF across morning/day shifts were compared between workers with occupational asthma, confirmed using specific challenge testing, and non-working asthmatics...
متن کاملImproving the quality of peak flow measurements for the diagnosis of occupational asthma.
INTRODUCTION Serial measurements of peak expiratory flow (PEF) are recommended in the evidence-based review list as the first stage in objective confirmation of occupational asthma. Different centres have reported widely different success in obtaining records of sufficient data quantity for diagnosis. We investigated different methods of instruction and determined the return rate and quality of...