Accuracy evaluation of a 3D-printed individual template for needle guidance in head and neck brachytherapy

نویسندگان

  • Ming-Wei Huang
  • Jian-Guo Zhang
  • Lei Zheng
  • Shu-Ming Liu
  • Guang-Yan Yu
چکیده

To transfer the preplan for the head and neck brachytherapy to the clinical implantation procedure, a preplan-based 3D-printed individual template for needle insertion guidance had previously been designed and used. The accuracy of needle insertion using this kind template was assessed in vivo In the study, 25 patients with head and neck tumors were implanted with 125I radioactive seeds under the guidance of the 3D-printed individual template. Patients were divided into four groups based on the site of needle insertion: the parotid and masseter region group (nine patients); the maxillary and paranasal region group (eight patients); the submandibular and upper neck area group (five patients); and the retromandibular region group (six patients). The distance and angular deviations between the preplanned and placed needles were compared, and the complications and time required for needle insertion were assessed. The mean entrance point distance deviation for all 619 needles was 1.18 ± 0.81 mm, varying from 0.857 ± 0.545 to 1.930 ± 0.843 mm at different sites. The mean angular deviation was 2.08 ± 1.07 degrees, varying from 1.85 ± 0.93 to 2.73 ± 1.18 degrees at different sites. All needles were manually inserted to their preplanned positions in a single attempt, and the mean time to insert one needle was 7.5 s. No anatomical complications related to inaccurately placed implants were observed. Using the 3D-printed individual template for the implantation of 125I radioactive seeds in the head and neck region can accurately transfer a CT-based preplan to the brachytherapy needle insertion procedure. Moreover, the addition of individual template guidance can reduce the time required for implantation and minimize the damage to normal tissues.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A digital model individual template and CT-guided 125I seed implants for malignant tumors of the head and neck

To enhance the accuracy of radioactive seed implants in the head and neck, a digital model individual template, containing information simultaneously on needle pathway and facial features, was designed to guide implantation with CT imaging. Thirty-one patients with recurrent and local advanced malignant tumors of head and neck after prior surgery and radiotherapy were involved in this study. Be...

متن کامل

Side effects of CT-guided implantation of 125I seeds for recurrent malignant tumors of the head and neck assisted by 3D printing non co-planar template

BACKGROUND For the recurrence of head and neck cancer after operation and radiotherapy, the local control of radioactive seed implantation is good, and it has a certain palliative effect. This study aims to investigate the acute and late side effects of a three-dimentional printing non co-planar template (3D-PNCT) for computed tomography (CT)-guided radioactive 125I seed (RIS) implantation in r...

متن کامل

Developing a Verification and Training Phantom for Gynecological Brachytherapy System

Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

متن کامل

Three-dimensional transrectal ultrasound guided high-dose-rate prostate brachytherapy: A comparison of needle segmentation accuracy with two-dimensional image guidance.

PURPOSE Conventional transrectal ultrasound guided high-dose-rate prostate brachytherapy (HDR-BT) uses an axially acquired image set for organ segmentation and 2D sagittal images for needle segmentation. Sagittally reconstructed 3D (SR3D) transrectal ultrasound enables both organ and needle segmentation and has the potential to reduce organ-needle alignment uncertainty. This study compares the ...

متن کامل

RadVision integration with TRUS robot for Brachytherapy

The main goal of this project is to integrate the RadVision treatment planning software with the (Trans-Rectal Ultrasound ) or TRUS robot. The TRUS robot is used in place of a physical template for placing the radioactive seeds in prostate brachytherapy, a treatment for prostate cancer. This integration should allow the surgeon to position the needle of the robot more accurately with the new sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 57  شماره 

صفحات  -

تاریخ انتشار 2016