A Position-Sensitive Ionization Chamber for Thermal Neutrons
نویسندگان
چکیده
A position-sensitive neutron detector based on He is being developed for a national crystal backscattering spectrometer (CBS) at a pulsed neutron source. It comprises a single gas volume, of constant depth, in the form of an annulus that is also part of a truncated cone. Charge from each event is collected on one or two anode strips, out of a total 336 around the annulus, yielding an angular resolution of about 1 . Low-noise signal processing, in the form of a monolithic preamplifier/shaping amplifier connected to each anode strip, provides electronic noise that is small enough to permit detector operation in ionization mode. In addition, the segmented anodes ensure near complete induced charge collection. This new detector therefore has significant advantages over previous detectors used in CBS instruments, which primarily consisted of arrays of individual He filled cylindrical counters with dead regions and nonuniform detection efficiency. The optimization of gas mixture/pressure, drift field, and shaping time is significant in achieving successful performance in the new detector.
منابع مشابه
Evaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731
Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...
متن کاملHigh-pressure Helium-3 Scintillation Position-sensitive Detector of Thermal Neutrons
The objective of this study is to demonstrate the feasibility of constructing a compact neutron detector that is sensitive to thermal and epithermal neutrons and has high rejection efficiency relative to gamma-ray background. A two-channel high-pressure He scintillation detector is considered for the detection of neutrons in coincidence mode. The detector consists of two large avalanche photodi...
متن کاملDevelopment of a Position Sensitive Neutron Detector with High Efficiency and Energy Resolution for Use at High-Flux Beam Sources
We are developing a high-efficiency neutron detector with 1 cm position resolution and coarse energy resolution for use at high-flux neutron source facilities currently proposed or under construction. The detector concept integrates a segmented (3)He ionization chamber with the position sensitive, charged particle collection methods of a MicroMegas detector. Neutron absorption on the helium pro...
متن کاملFabrication of Free Air Well Type Ionization Chamber and Calculational Assessment and Measurement of Its Operational Characteristics
Introduction: Well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. The chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. For the measurements, the brachytherapy sources are transferred to the middle of the tube. Materials and Methods: For designing the well type chamber, the measu...
متن کاملطراحی و ساخت اتاقک یونش حلقوی شکل با الکترود های محافظ گرافیتی
The development of a graphite ionization chamber in Iran is reported for first time, using graphite coatings collecting electrodes and guard rings. Its sensitive volume is about 200cm³, with a shape of a ring which is different from its older equivalents and a 7cm central hole that allows the passage of the direct radiation beam without attenuation. This kind of ionization chamber has alre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -