A controlled trial of smart infusion pumps to improve medication safety in critically ill patients.
نویسندگان
چکیده
OBJECTIVE Intravenous medications are vital during inpatient management. Errors associated with the administration of medications through intravenous infusion pumps to critically ill patients can result in adverse drug events. We sought to assess the impact of smart pumps with integrated decision support software on the incidence and nature of medication errors and adverse drug events. DESIGN We performed a prospective, randomized time-series trial and compared the serious medication error rate between intervention (decision support on) and control (decision support off) periods. Serious medication errors included both near-misses and preventable adverse drug events. Pump software produced log reports to help identify potential events. Events were presented to physicians for rating of event type, preventability, and severity. SETTING Cardiac surgical intensive care and step-down units between February and December 2002. PATIENTS Pump data were available for 744 cardiac surgery admissions. INTERVENTIONS Decision support during medication administration provided feedback including alerts, reminders, and unit-specific drug rate limits. MEASUREMENTS AND MAIN RESULTS We found a total of 180 serious medication errors, including 14 and 11 preventable adverse drug events and 73 and 82 nonintercepted potential adverse drug events in the control and intervention periods, respectively. The serious medication error rates in the control and intervention periods were 2.03 and 2.41 per 100 patient-pump-days, respectively (p = .124). We also found numerous opportunities for safety improvement. Violations of infusion practice during the intervention periods included 571 (25%) bypasses of the drug library. Medications were also frequently administered without documentation of physician orders in both periods (n = 823; 7.7%). CONCLUSION Intravenous medication errors and adverse drug events were frequent and could be detected using smart pumps. We found no measurable impact on the serious medication error rate, likely in part due to poor compliance. Although smart pumps have great promise, technological and nursing behavioral factors must be addressed if these pumps are to achieve their potential for improving medication safety.
منابع مشابه
Intelligent Intravenous Infusion Pumps to Improve Medication Administration Safety
Intravenous (IV) medications are vital in the management of hospitalized patients. Inpatients frequently receive several IV medications concurrently, and these are commonly delivered with infusion pump systems. In particular, critically ill patients receive potent "high-alert" IV drugs, many with narrow safety margins requiring careful nursing titration. However, while intravenous medications h...
متن کاملBenefits and risks of using smart pumps to reduce medication error rates: a systematic review.
BACKGROUND Smart infusion pumps have been introduced to prevent medication errors and have been widely adopted nationally in the USA, though they are not always used in Europe or other regions. Despite widespread usage of smart pumps, intravenous medication errors have not been fully eliminated. OBJECTIVE Through a systematic review of recent studies and reports regarding smart pump implement...
متن کاملEvaluation of Use of Electronic Patient Controlled Analgesia Pumps to Improve Patient Safety in an Academic Medical Center
Patient controlled analgesia (PCA) and Patient-controlled epidural analgesia (PCEA) pumps are methods of pain control with complex smart infusion devices and are widely used in hospitals. Smart PCA/PCEA pumps can be programmed with the dose and rate of medications within pre-set ranges. However, adverse effects have been reported associated with these pumps' use. In this paper, we describe a pr...
متن کاملThe effects of foot massage on physiologic indicators in critically ill patients
The perpuse of this research is to determine the effect of foot massage on physiologic indicators including pulse, respiration and mean arterial pressure. The hypothesis of this research is that foot massage decreases the patient´s heart rate, respiratory rate and mean arterial pressure. This research is a quasiexperimental study and a self-control clinical trial with repeated measures in witch...
متن کاملAminophylline Infusion Induced Excretion of Magnesium During Magnesium Loading Test in Critically Ill Patients
The aim of this study was to investigate the prevalence of Mg deficiency and effect of aminophylline infusion on urine magnesium concentration after magnesium loading test (MLT). To determine serum Mg, venous blood specimens were obtained just before the first MLT. Two MLTs were performed. The first one was done before starting aminophylline infusion and the 2nd one was done du...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Critical care medicine
دوره 33 3 شماره
صفحات -
تاریخ انتشار 2005