CBN 13-1 Design and Beam Test Results of CHESS Compact Undulator
نویسندگان
چکیده
We developed, built and beam tested a novel, compact, in-vacuum undulator magnet based on an adjustable phase (AP) scheme. The undulator is 1 m long with a 5mm gap. It has a pure permanent magnet structure with 24.4mm period and 1.1 Tesla maximum peak field. The device consists of two planar magnet arrays mounted on rails inside of a rectangular box-like frame with 156 mm x 146 mm dimensions. The undulator magnet is enclosed in a 273 mm (10.75”) diameter cylindrical vacuum vessel with a driver mechanism placed outside. In May 2012 the CHESS Compact Undulator (CCU) was installed in Cornell Electron Storage Ring and beam tested. During four weeks of dedicated run we evaluated undulator radiation properties as well as magnetic, mechanical and vacuum properties of the undulator magnet. We also studied the effect of the CCU on storage ring beam. The spectral characteristics and intensity of radiation were found to be in very good agreement with expected. The magnet demonstrated reproducibility of undulator parameter K at 1.4 x10 -4 level. It was also found that the undulator K parameter change does not affect electron beam orbit and betatron tunes.
منابع مشابه
CBN 10-6 (Undulators for CHESS)
Presently we are developing a novel type of undulator magnet optimized to use in coherent light sources such as FEL and ERL (Temnykh, 2008). Undulator (we call it Delta) consists of four magnet arrays arranged symmetrically around beam axis as shown in Fig.1. Arrays are mounted inside of box-like frame on rails. Rails provide longitudinal displacement of the arrays which used to control magneti...
متن کاملCbn 08-2 Evaluation of the Low Cost Compact Ppm Planar Undulator Model
To evaluate a number of ideas, which, in principal, can be implemented in the ERL insertion devices design, we built and tested 30cm long pure permanent magnet (PPM) undulator model. The model had 25.4mm undulator period, 5mm fixed gap and ∼ 1.07T maximum peak field on the beam axes. For the field strength control was utilized the phase adjustment scheme in which magnetic arrays are moved longi...
متن کاملCbn 10-2
We describe design of optimized undulator with SC windings able to generate magnetic field of opposite helicities, including elliptic and a linear ones oriented as desired. For undulator period 25mm, aperture 8mm, length ~10m (single piece), K factor could be changed from zero up to 1.5 by changing the feeding current. 1. OVERVIEW Undulators are planned for installation in all SR facilities. Un...
متن کاملEvaluation of Magnetic and Mechanical Properties of Delta Undulator
The paper describes a test result of a Delta undulator prototype recently built at CLASSE (Cornell Laboratory for Accelerator-based Sciences and Education). This undulator design is optimized for the linac type beam. It has a round bore, very compact, provides full polarization control and has magnetic field significantly stronger than in a conventional undulator. We are planning to use Delta u...
متن کاملA compact design for beam transport
A double-achromatic, double-focusing magnet system of very small size is described which will be used in the injection line for an undulator in a FEL experiment . Because of the double focusing no quadrupoles are needed between the dipole, which couples the electrons in the FEL cavity, and the undulator. An example will be worked out for an electron bunch of 25 MeV, 100 Awhich is focused on a s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -