Applicability of extracellular electrical impedance tomography in monitoring respiratory tract inflammation.
نویسندگان
چکیده
BACKGROUND The presence of persistent mild inflammation is widely considered to provide the immunopathogenic basis for bronchial, nasal, or sinusal inflammation between critical phases and in asymptomatic periods. Exhaled nitric oxide (NO) is currently the most reliable marker of rhinobronchial inflammation, but its routine assessment is difficult as the test is available only in highly specialized centers. OBJECTIVE The aim of this study was to evaluate the agreement between a new diagnostic method (extracellular electrical impedance tomography) and immunological and clinical symptom scores, anterior rhinomanometry, peak expiratory flow rate (PEFR), serum eosinophil cationic protein (ECP) level, and blood eosinophil count in the clinical monitoring of respiratory tract inflammation before and after treatment of asthma or rhinitis. PATIENTS AND METHODS Eighty-seven patients were studied; 73 had mild persistent asthma (PEFR > or = 20% below predicted) and 14 had rhinitis. At baseline (TO), the patients underwent a medical examination to record symptom scores, PEFR, anterior rhinomanometry, an extracellular electrolytic conductivity test (bioimpedance tomography), serum ECP level and blood eosinophil count. Appropriate treatment was prescribed, following the guidelines of the Global Initiative for Asthma and the Allergic Rhinitis and Its Impact on Asthma. After 21 days of therapy (T1), the patients were re-evaluated for the same parameters. RESULTS AND CONCLUSIONS This study demonstrates the good agreement (Cohen's kappa = 0.689) between the symptom scores of patients with rhinitis and the findings of extracellular tomography and very good agreement (kappa = 0.846) between symptom scores of asthma patients and extracellular tomography. These findings validate the use of this new technique for the real-time monitoring and adjustment of treatment in these clinical settings.
منابع مشابه
Electrical impedance tomography as ventilation monitoring in ICU patients
Electrical impedance tomography (EIT), as a monitoring tool of regional lung ventilation, is radiation-free imaging with high temporal resolution. The most important purpose of EIT is to visualize the distribution of tidal volume in different lung regions especially between dependent (dorsal in supine patients) and non-dependent (ventral in supine patients) regions. Many clinical studies evalua...
متن کاملUse of thoracic electrical impedance tomography as an auxiliary tool for alveolar recruitment maneuvers in acute respiratory distress syndrome: case report and brief literature review
Thoracic electrical impedance tomography is a real-time, noninvasive monitoring tool of the regional pulmonary ventilation distribution. Its bedside use in patients with acute respiratory distress syndrome has the potential to aid in alveolar recruitment maneuvers, which are often necessary in cases of refractory hypoxemia. In this case report, we describe the monitoring results and interpretat...
متن کاملLiterature List Electrical Impedance Tomography
Amniotic fluid embolism is a rare peripartum complication with the sudden onset of haemodynamic instability, respiratory failure and coagulopathy during labour or soon after delivery. A 31-year-old woman with amniotic fluid embolism was treated with vasopressors, inotropes, intravenous fluid, tranexamic acid and ventilatory support. Assessment of respiratory impairment was made using convention...
متن کاملElectrical impedance tomography and trans-pulmonary pressure measurements in a patient with extreme respiratory drive
Preserving spontaneous breathing during mechanical ventilation prevents muscle atrophy of the diaphragm, but may lead to ventilator induced lung injury (VILI). We present a case in which monitoring of trans-pulmonary pressure and ventilation distribution using Electrical Impedance Tomography (EIT) provided essential information for preventing VILI.
متن کاملMonitoring of the lung fluid movement and estimation of lung area using Electrical Impedance Tomography: A Simulation Study
Patients suffering from the acute respiratory distress syndrome (ARDS) requires thoracic electrical impedance tomography (EIT) for the monitoring their conditions ranging from dynamic shifting of body fluids to lung aeration right at the bedside. More objectively, EIT-derived numeric parameters would help the physician to evaluate the state of the lung. Thus, here we have performed a Finite Ele...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of investigational allergology & clinical immunology
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2007