Intracoronary radiation for prevention of restenosis: dose perturbations caused by stents.

نویسندگان

  • H I Amols
  • F Trichter
  • J Weinberger
چکیده

BACKGROUND Intravascular irradiation with beta-emitters has been proposed for inhibition of restenosis in coronary arteries after balloon angioplasty or stent implantation. Previous studies have shown the effectiveness of gamma-radiation to prevent recurrent restenosis, even in the presence of an implanted stent. The limited range of beta-particles compared with gamma-radiation, however, opens the question of whether absorption and scattering of beta-particles by stent struts will cause significant perturbations in the uniformity and magnitude of the radiation dose, which may in turn compromise treatment. METHODS AND RESULTS Nine different stents were deployed with a balloon filled with a beta-emitting radioactive liquid. Dose distributions were measured with Gafchromic film. Stents varied significantly in their absorption of beta-particles. Some stents, constructed of fine meshed wires, produced minimal dose perturbations. Others, with thicker, high-atomic-number struts, induced cold spots in the dose distribution adjacent to the wires of </=35%. Average dose reduction varied from 4% to 14% in the presence of various stents. CONCLUSIONS Radiation strategy may have to be tailored to stent design. Stents that minimally perturb the dose distribution may be deployed before irradiation. Those that significantly alter the radiation dose might be better deployed after irradiation. Dose prescriptions may require modification if such perturbations prove clinically significant. Observed dose perturbations, however, decreased rapidly with increasing distance from the stent, which may mitigate the clinical impact of these findings. This, as well as the effects of stents on gamma-dose distributions, requires further investigation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

Dosimetric Measurements in Isolated Human Coronary Arteries Comparison of Commercially Available Iridium With Strontium/Yttrium Emitters

Background—Intravascular brachytherapy is being applied more and more in patients with coronary artery disease for the prevention of restenosis subsequent to balloon angioplasty, in particular after stent implantation. Several radiation sources ( and -emitters) are available in clinical routine. It was the purpose of this study to compare the radiation doses at the level of the adventitia in di...

متن کامل

Modeling and dose calculations of a pure beta emitting 32P coated stent for intracoronary brachytherapy by Monte Carlo code

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

متن کامل

Intracoronary brachytherapy for the prevention and management of restenosis.

Patients who undergo percutaneous transluminal coronary angioplasty (PTCA) for coronary artery disease are at risk for recurrence at the site of the procedure. Placement of stents as an adjunct to PTCA is one strategy to reduce recurrence. The use of various techniques to apply intracoronary radiation through local application of catheters or placement of radioactive stents (also known as intra...

متن کامل

Dosimetric measurements in isolated human coronary arteries: comparison of commercially available iridium(192) with strontium/yttrium(90) emitters.

BACKGROUND Intravascular brachytherapy is being applied more and more in patients with coronary artery disease for the prevention of restenosis subsequent to balloon angioplasty, in particular after stent implantation. Several radiation sources (beta- and gamma-emitters) are available in clinical routine. It was the purpose of this study to compare the radiation doses at the level of the advent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 98 19  شماره 

صفحات  -

تاریخ انتشار 1998