NASPE training requirements for cardiac implantable electronic devices: selection, implantation, and follow-up.

نویسندگان

  • David L Hayes
  • Gerald V Naccarelli
  • Seymour Furman
  • Victor Parsonnet
  • Dwight Reynolds
  • Nora Goldschlager
  • Paul Gillette
  • James D Maloney
  • Leslie Saxon
  • Angel Leon
  • Emile Daoud
چکیده

Cardiac implantable electronic devices (CIEDs) have become frequently used therapeutic modalities. CIEDs include pacemakers, implantable cardioverter defibrillators (ICDs), devices for heart failure management (cardiac resynchronization), and implantable hemodynamic monitors. Selection of the appropriate CIED, its implantation, and follow-up care require expertise to achieve optimal therapeutic results. Training requirements in cardiac pacing have previously been defined by the North American Society of Pacing and Electrophysiology (NASPE) and the American College of Cardiology (ACC).1−3 In the initial report of the NASPE Policy Conference Training Requirements for Permanent Pacemaker Selection, Implantation, and Follow-Up, core training requirements in cardiac pacing were defined. NASPE believed that defining core training guidelines was especially important for this discipline because pacemaker and ICD selection, implantation, and follow-up are performed by various medical and surgical specialists, including cardiologists, internists, general surgeons, cardiothoracic surgeons, and pediatric cardiologists. Because training is obviously quite different for each discipline, and core knowledge and training for pacemaker therapy are potentially varied, it is critical that there be definitions for training.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Remote Monitoring of Cardiac Implantable Electronic Devices

Pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization devices use advanced diagnostic functions to continuously monitor the patient and the device itself. Follow-up is necessary after implantation to provide individualized treatment and to detect malfunctions. Routine office visits, however, do not provide access to these data on a timely basis. Transtelephonic pace...

متن کامل

Adverse Interactions between ICD and Permanent Pacemaker Systems

After the introduction of the implantable cardioverter defibrillator (ICD) in clinical practice by Mirowski in 1980 [Mirowski et al., 1980] the first available devices offered only a basic ventricular pacing option. Since approximately 5-20% of patients with an indication for ICD therapy following implantation criteria at that time (secondary prevention) needed antibradycardia pacing as well, t...

متن کامل

Task force 6: training in specialized electrophysiology, cardiac pacing, and arrhythmia management endorsed by the Heart Rhythm Society.

T ( H r l i p p p r a linical cardiac electrophysiology and cardiac pacing have erged into a common cardiac subspecialty discipline. Comlex cardiac arrhythmias are managed by physicians with pecial expertise in cardiac electrophysiology, the use of cardiac mplantable electrical devices (CIEDs), and the application of ther interventional ablative techniques and pharmacologic reatments. Cardiac i...

متن کامل

The role(s) of the industry employed allied professional.

March 2001 PACE, Vol. 24 Introduction Industry employed allied professionals (IEAPs) have traditionally played an important role providing technical assistance to physicians and their clinically employed allied professionals (CEAPs) during pacemaker/ICD implantation, programming, troubleshooting, and follow-up. The IEAPs include directly employed or contracted manufacturer representatives, fiel...

متن کامل

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 26 7 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2003