On-chip solid-phase extraction pre-concentration/focusing substrates coupled to atmospheric pressure matrix-assisted laser desorption/ionization ion trap mass spectrometry for high sensitivity biomolecule analysis.
نویسندگان
چکیده
Atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) has proven a convenient and rapid method for ion production in the mass spectrometric (MS) analysis of biomolecules. AP-MALDI and electrospray ionization (ESI) sources are easily interchangeable in most mass spectrometers. However, AP-MALDI suffers from less-than-optimal sensitivity due to ion losses during transport from the atmosphere into the vacuum of the mass spectrometer. Here, we study the signal-to-noise ratio (S/N) gains observed when an on-chip dynamic pre-concentration/focusing approach is coupled to AP-MALDI for the MS analysis of neuropeptides and protein digests. It was found that, in comparison with conventional AP-MALDI targets, focusing targets showed (1) a sensitivity enhancement of approximately two orders of magnitude with S/N gains of 200-900 for hydrophobic substrates, and 150-400 for weak cation-exchange (WCX) substrates; (2) improved detection limits as low as 5 fmol/microL for standard peptides; (3) significantly reduced matrix background; and (4) higher inter-day reproducibility. The improved sensitivity allowed successful tandem mass spectrometric (MS/MS) sequencing of dilute solutions of a derivatized tryptic digest of a protein standard, and enabled the first reported AP-MALDI MS detection of neuropeptides from Aedes aegypti mosquito heads.
منابع مشابه
Atmospheric pressure MALDI/ion trap mass spectrometry.
A new sample ionization technique, atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI), was coupled with a commercial ion trap mass spectrometer. This configuration enables the application-specific selection of external atmospheric ionization sources: the electrospray/APCI (commercially available) and AP MALDI (built in-house), which can be readily interchanged within mi...
متن کاملElectrospray sample deposition for matrix-assisted laser desorption/ionization (MALDI) and atmospheric pressure MALDI mass spectrometry with attomole detection limits.
Electrospray sample deposition was explored for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). In this method, nanoliter volumes of matrix/analyte mixture were electrosprayed from a high voltage biased (1-2 kV) fused-silica capillary onto a grounded MALDI plate mounted 100-500 microm from the capillary outlet. Electrospray deposition with these condi...
متن کاملIdentification of phenolic compounds in rosemary honey using solid-phase extraction by capillary electrophoresis-electrospray ionization-mass spectrometry.
Complex extracts of rosemary honey constituents often require very effective separation techniques to allow the identification of different compounds. Capillary electrophoresis (CE) coupled to mass spectrometry (MS) detection can provide structure-selective information about the analytes in such matrices and has turned out to be an attractive alternative to HPLC methods. A simple and cost-effec...
متن کاملAtmospheric pressure MALDI Fourier transform mass spectrometry of labile oligosaccharides.
An atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) source coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT ICR MS) under UV laser and solid matrix conditions has been demonstrated to analyze a variety of labile oligosaccharides including O-linked and N-linked complex glycans released from glycoproteins. Spectra were acquired by both AP MALDI...
متن کاملAdvantages of Orthogonal Nebulizer Orientation in Electrospray for Quadrupole and Ion Trap Mass Spectrometers
With the increasing popularity of atmospheric pressure ionization (API) mass spectrometric techniques, electrospray ionization has become a widespread tool for quantitative determinations. When the sample matrix is complex, electrospray ionization can result in the formation of nondesolvated, charged residues as well as analyte ions (see Figure 1). These nondesolvated residues contaminate the i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Rapid communications in mass spectrometry : RCM
دوره 23 4 شماره
صفحات -
تاریخ انتشار 2009