Successful Percutaneous Coronary Intervention through a Severely Bent Artificial Ascending Aorta Using the DIO Thrombus Aspiration Catheter

نویسندگان

  • Akinori Fujikake
  • Takaaki Komatsu
  • Isao Taguchi
چکیده

A 66-year-old man was admitted to our institute because of chest pain. He had undergone replacement of the ascending aorta due to aortic dissection 9 years previously. We made a diagnosis of acute coronary syndrome, and coronary artery angiography was performed. Although the right coronary artery was successfully cannulated, a severe bend of the artificial aorta made it very difficult to advance the catheter into the left coronary artery. Ultimately, a DIO thrombus aspiration catheter was used to enter the left coronary artery, and a stent was implanted successfully. The DIO catheter is very useful when the selection of a guiding catheter is complicated, such as in the case of severe vessel tortuosity or a bend of the ascending aorta.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Rotational Atherectomy for an Angulated Calcified Lesion in an Anomalous Right Coronary Artery Using the “Mother-and-Child” Technique

Percutaneous coronary intervention (PCI) involving the anomalous coronary artery is challenging with respect to difficulty in achieving stable catheterization. Rotational atherectomy (RA) can facilitate severely calcified lesions to improve stent delivery and stent expansion; however, its utility in tortuous and angulated coronary arteries is limited with difficulty in delivery of the RA burr. ...

متن کامل

Successful coronary stent retrieval from the ascending aorta using a gooseneck snare kit

Coronary stent dislodgement is a rare complication of percutaneous coronary intervention. We report a case of stent dislodgement in the ascending thoracic aorta. The stent was mechanically distorted in the left circumflex artery (LCX) while being delivered to the proximal LCX lesion. The balloon catheter was withdrawn, but the stent with the guide wire was remained in the ascending thoracic aor...

متن کامل

A case of successful reperfusion through a combination of intracoronary thrombolysis and aspiration thrombectomy in ST-segment elevation myocardial infarction associated with an ectatic coronary artery

BACKGROUND Large thrombus burdens in ectatic coronary arteries that remain after aspiration thrombectomy can negatively impact outcomes following percutaneous coronary interventions in patients with acute myocardial infarction. CASE PRESENTATION A 53-year-old man presented with ST-segment elevation myocardial infarction (STEMI). Coronary angiography revealed an ectatic right coronary artery (...

متن کامل

ST-Elevation Myocardial Infarction, Thrombus Aspiration, and Different Invasive Strategies. A TASTE Trial Substudy

BACKGROUND The clinical effect of thrombus aspiration in ST-elevation myocardial infarction may depend on the type of aspiration catheter and stenting technique. METHODS AND RESULTS The multicenter, prospective, randomized, open-label trial Thrombus Aspiration in ST-Elevation myocardial infarction in Scandinavia (TASTE) did not demonstrate a clinical benefit of thrombus aspiration compared to...

متن کامل

GuideLiner Catheter Use for Percutaneous Intervention Involving Anomalous Origin of a Single Coronary Trunk Arising from the Ascending Aorta

Cases in which an anomalous single coronary trunk arises from the ascending aorta are extremely rare. In percutaneous coronary intervention for the lesion of a coronary artery anomaly, several problems may occur, including selection of a guide catheter, insufficient backup force, and difficulties of stent delivery. The GuideLiner catheter, which is a coaxial guide extension having the advantage...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016