Body segment parameters of young Chinese men determined with magnetic resonance imaging.
نویسندگان
چکیده
INTRODUCTION This study determines Chinese body segment parameters based on a magnetic resonance imaging method. METHODS Fifty young Chinese men (21.5 ± 1.52 yr) participated in this study. Magnetic resonance images were obtained using a GE magnetic resonance imaging 1.5-T scanner with 10-mm thickness. The magnetic resonance digital images were analyzed using medical imaging software. This study separated the human body into 14 segments, including the head and neck, trunk, upper arm, forearm, hand, thigh, shank, and foot to calculate the percentage of mass of total body mass (%M), center of mass location (%CM), and moments of inertia (I) for each segment. RESULTS The study results showed %M and %CM of the head and neck (8.21 and 52.69), trunk (42.28 and 41.96), upper arm (3.25 and 47.16), forearm (1.36 and 40.98), hand (0.54 and 32.60), thigh (13.50 and 48.56), shanks (4.63 and 41.68), and foot (1.47 and 47.51). Compared with other cadaver-based and in vivo studies, our findings indicate a lower %M and %CM at the hand, forearm, and trunk but higher %M and %CM at the head. The differences may be due to the race, lifestyle, age, and level of participants. The discrepancies in segment boundaries and coordinate system may also contribute to these differences. Most previous studies have either used cadavers from older Caucasian men or drawn conclusions from a limited sample size. CONCLUSIONS This study establishes a new model to provide thorough information of Chinese body segment parameters for enhanced ergonomic design and more accurate human movement studies.
منابع مشابه
An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter
Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...
متن کاملRelationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction
Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...
متن کاملSize Reproducibility of Gadolinium Oxide Based Nanomagnetic Particles for Cellular Magnetic Resonance Imaging: Effects of Functionalization, Chemisorption and Reaction Conditions
We developed biofunctionalized nanoparticles with magnetic properties by immobalizing diethyle-neglycol (DEG) on Gd2O3, and PEGilation of small particulate gadolinium oxide (SPGO) with two me-thoxy-polyethyleneglycol-silane (mPEG-Silane 550 and 2000 Da) using a new supervised polyol route, described recently. In conjunction to the previous study to achieve a high quality synthesis and increase ...
متن کاملSize Reproducibility of Gadolinium Oxide Based Nanomagnetic Particles for Cellular Magnetic Resonance Imaging: Effects of Functionalization, Chemisorption and Reaction Conditions
We developed biofunctionalized nanoparticles with magnetic properties by immobalizing diethyle-neglycol (DEG) on Gd2O3, and PEGilation of small particulate gadolinium oxide (SPGO) with two me-thoxy-polyethyleneglycol-silane (mPEG-Silane 550 and 2000 Da) using a new supervised polyol route, described recently. In conjunction to the previous study to achieve a high quality synthesis and increase ...
متن کاملMagnetic Resonance Imaging-Based Morphometric Assessment of Sexual Dimorphism of Corpus Callosum
Introduction: Interhemispheric transmission of signal is done by corpus callosum (CC) as the largest fiber tract in brain. CC comprised 5 segments of rostrum, genu, body, isthmus, and splenium. Contradictory reports exist about sexual dimorphism of CC. We designed this study to assess probable sexual differences of CC and its different parts in men and women. Methods: We analyzed magnetic reso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medicine and science in sports and exercise
دوره 45 9 شماره
صفحات -
تاریخ انتشار 2013