A comparison of cardiac output determined by the Fick procedure and a direct method using the rotameter.
نویسندگان
چکیده
Experiments were performed on the anesthetized dog to determine the accuracy of the widely used Fick procedure. Cardiac output values, recorded by an optical rotameter, served as a reliable standard for comparison. Under the conditions of these experiments, comparisons showed excellent agreement. The average variation between the two series of the measurements was ±5 per cent. Twelve of thirteen comparisons agreed within less than ±8 per cent. This small deviation was within the range of error which might have existed on the basis of known technical inaccuracies.
منابع مشابه
Comparison of cardiac output determined by a carbon dioxide-rebreathing and direct Fick method at rest and during exercise.
1. To study the validity of a CO2-rebreathing method at rest and during graded exercise, cardiac output was measured simultaneously on 59 occasions in 16 subjects with normal pulmonary function with the CO2-rebreathing method and the direct Fick method for oxygen. The correlation coefficient between the results of both methods was significantly higher during exercise than at rest. 2. No systema...
متن کاملComparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method.
BACKGROUND Cardiac output can be determined by using a variety of methods. OBJECTIVES To determine the precision and bias between 3 methods for determining cardiac output: bioimpedance, thermodilution, and the Fick method. METHODS Cardiac output was determined by using bioimpedance via neck and thorax patches and thermodilution via pulmonary artery catheter in 46 patients in the intensive c...
متن کاملA Comparison of the Direct Fick and the Grollman Methods for Determination of the Cardiac Output in Man.
The introduction of the cardiac catheter by Forssman (1) and its later development as a useful physiological instrument by Cournand (2, 3) have made possible the determination of the cardiac output by the direct Fick principle in man (4). Using this method, a number of investigators have reported values of 5.5 to 6.5 liters per minute for the basal cardiac output, which correspond to 3.1 to 3.8...
متن کاملComparison of Cardiac Output Determinedby the Ballistocardiograph
a study of the latter method. In the form of an apparatus first developed in this country by Starr and his colleagues (2), the ballistocardiograph was designed to measure cardiac output. In normal resting subjects a reasonably satisfactory agreement with cardiac output measured by other techniques was obtained (3, 4). However, the validity of the ballistic record as a measure of cardiac output ...
متن کاملComparison of Cardiac Output Determinedby the Ballistocardiograph ( Nickerson
a study of the latter method. In the form of an apparatus first developed in this country by Starr and his colleagues (2), the ballistocardiograph was designed to measure cardiac output. In normal resting subjects a reasonably satisfactory agreement with cardiac output measured by other techniques was obtained (3, 4). However, the validity of the ballistic record as a measure of cardiac output ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 1 6 شماره
صفحات -