The relationship between resonance frequency analysis (RFA) and lateral displacement of dental implants: an in vitro study.
نویسندگان
چکیده
This in vitro investigation was conducted to study the relationship between resonance frequency analysis (RFA) and lateral displacement measurements of dental implants. A total of 30 implant sites were prepared in nine fresh bovine bone specimens. The bone density around each preparation was determined by using cone beam computerized tomography (CBCT) and imaging software. Dental implants were then inserted during continuous registration of insertion torque. RFA measurements were performed in perpendicular and parallel to the long axis of the specimens. The bone blocks were embedded in plaster and fixated in a specially designed rig for displacement measurements. A lateral force of 25 N was applied via an abutment perpendicular and parallel to each implant and the displacement measured in μm. In addition, a flex constant (μm N(-1) ) was calculated for each measurement. There was a significant inverse correlation between RFA and lateral implant displacement (μm) measurements and between RFA measurements and the flex constant in both perpendicular and parallel directions in bone (P ≤ 0·001). Moreover, both RFA and displacement measurements correlated with bone density (P ≤ 0·001). It is concluded that RFA measurements reflect the micromobility of dental implants, which in turn is determined by the bone density at the implant site.
منابع مشابه
Resonance frequency analysis of implant stability in augmented and non-augmented sinus sites
Background and aim: Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...
متن کاملRESONANCE FREQUENCY ANALYSIS FOR IMPLANT STABILITY MEASUREMENTS. A review
The resonance frequency analysis (RFA) technique for implant stability measurements was developed by Meredith and coworkers more than 20 years ago. RFA makes use of a transducer (peg), which is attached to the implant and excited over a range of frequencies by electro-magnetic waves to measure the resonance frequency (RF) of the transducer. The underlying RF measurements in Hz are translated to...
متن کاملبررسی شدت نسبی سیگنال تصاویر Magnetic Resonance در بافت رترودیسکال و عضله پتریگوئید خارجی و رابطه آن با یافتههای Magnetic Resonance Imaging
Background and Aims: Disc displacement is the most common temporomandibular joint disorder and magnetic resonance imaging (MRI) is the gold standard in its diagnosis. This disorder can lead to changes in signal intensity of magnetic resonance (MR). The purpose of this study was evaluation of correlation between relative signal intensity of MR images of retrodiscal tissue, superior and inferior ...
متن کاملThe comparison between implant stability quotient and bone-implant contact revisited: an experiment in Beagle dog.
BACKGROUND Resonance frequency analysis (RFA) is applied clinically for the assessment of implant stability, and the relevance of this application is widely accepted. However, the relationship between resonance frequency (RF) and other parameters of implant stability, such as the histomorphometrical bone-to-implant contact (BIC) parameter, has become controversial in the last decade. OBJECTIV...
متن کاملIn vitro evaluation of resonance frequency analysis values to different implant contact ratio and stiffness of surrounding material
PURPOSE The present study was aimed to evaluate the influence of implant contact ratio and stiffness of implant-surrounding materials on the resonance frequency analysis (RFA) values. MATERIALS AND METHODS Seventy resin blocks that had the different amounts (100, 50, 30, 15%) of resin-implant contact (RIC) were fabricated. Ten silicone putty blocks with 100% silicone-implant contact were also...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of oral rehabilitation
دوره 40 3 شماره
صفحات -
تاریخ انتشار 2013